5. After the completion of the Commit Changes process, you are returned to the [Emulex Adapter
Configuration Main Menu] screen.
FIGURE 2.64
Topology / Link Speed change confirmation (2)
Remarks
After changing the [Topology Selection] or [Force Link Speed] settings and then selecting [Discard Changes],
if you are returned to the screen for changing settings, the changes to the FC card settings have been discarded.
However, you may still see the changed settings displayed by the utility.
If so, select the FC card again from the menu as described in 2.3.4 Selecting an HBA, before proceeding with
the work.
Changing the setting of the opposing device
The setting of the opposing Fibre Channel switch and SAN storage unit disk array must also be made static so
that it corresponds to the static setting of the FC card.
For details on the settings required on the ETERNUS when connecting to it, see the ETERNUS manuals at the
following website:
http://www.fujitsu.com/global/services/computing/storage/eternus/documentation/