Programming The Output - Agilent Technologies N8900 series Operating Manual

Autoranging system dc power supply
Table of Contents

Advertisement

Programming the Output

When the power supply is first turned on, it may take about 30 seconds or so to initialize the instru-
ment before it is ready for use.
Set the Output Voltage
Set the Output Current
Enable the Output
Set the Output Voltage
You can set the output voltage when the output is either disabled (OFF) or enabled (ON). When enabled, the output
voltage will rise to the programmed setting. This assumes that a minimum output current has been programmed, that
the output has not reached its current limit or power limit boundary.
Front Panel
Turn the Voltage knob while observing the
voltage setting; or
Press the Voltage key, enter a value.
Then press Select.
When the unit is operating in constant voltage mode, CV status is displayed on the front panel.
Set the Output Current
You can set the output current when the output is either disabled (OFF) or enabled (ON). When enabled, the output cur-
rent will be limited at its programmed setting.
Front Panel
Turn the Current knob while observing
the current setting; or
Press the Current key, enter a Value.
Then press Select.
When the unit is operating in constant current mode, CC status is displayed on the front panel.
Enable the Output
Front Panel
Press the On/Off key.
Agilent N8900 Series Operating and Service Guide
SCPI Command
To set the output voltage to 90 volts:
VOLT 90
SCPI Command
To set the output current to 100 amps:
CURR 100
SCPI Command
To turn the output on or off:
OUTP ON|OFF
Programming the Output
53

Advertisement

Table of Contents
loading

Table of Contents