Agilent Technologies N8900 series Operating Manual page 66

Autoranging system dc power supply
Table of Contents

Advertisement

Pin Descriptions and Characteristics
Pin Descriptions
Pin
Name
1
VPROG
2
IPROG
3
VREF
4
DGND
5
ANALOG-ENAB
6
OT
7, 8
Not used
9
VMON
10
IMON
11
AGND
12
Not used
13
INHIBIT
14
OVP
15
CV
Pin Characteristics
Analog Input (pin 1, 2, 8)
Analog Output (pin 3, 9, 10)
Digital Inputs (pin 5, 13)
Digital Outputs (pin 6, 14, 15)
Reference voltage
Agilent N8900 Series Operating and Service Guide
Type
Description
Analog in
Programs output voltage. Only active when A-ENAB is low.
Analog in
Programs output current. Only active when A-ENAB is low.
Reference voltage. Can be connected to VPROG or IPROG directly to
Analog out
program full scale, or through potentiometers to adjust programmed
values.
Ground
Ground for digital inputs and outputs.
Digital in
Analog Enable. Enables analog programming when low.
Digital out
Over-temperature status indicator. High when OT is tripped.
Analog out
Voltage monitor signal.
Analog out
Current monitor signal.
Ground
Ground for analog inputs and outputs.
Digital in
Inhibits (turns off) output when low. Only active when A-ENAB is low.
Digital out
Over-voltage status indicator. High when OVP is tripped.
Digital out
Constant voltage status indicator. High when in CV mode.
Full scale voltage: 5 V or 10 V, depending on Menu:\System\IO\Analog setting.
Input resistance: 150 kΩ.
Full scale voltage: 5 V or 10 V, depending on Menu:\System\IO\Analog setting.
Drive with relay to ground or open-collector driver.
Open-circuit voltage: approximately 6.5 V.
Driver current sink requirement: < 0.4 V @ 3 mA
High state: 4.74 kΩ pull-up to approximately 10 V.
Low state sink capability: < 0.4 V @ 5 mA
Voltage: Fixed 5 V or 10 V, depending on Menu:\System\IO\Analog setting.
Analog Programming
65

Advertisement

Table of Contents
loading

Table of Contents