Assigning M/T GROUP INSERTS and OUTPUTS
The 8 blocks at the bottom of the GUI entitled M/T GRP, each with 7
clickable fields (including the title) are used to set up the multitrack
outputs and inserts.
FAST INSERT – Upper field
Clicking on the upper M/T GRP field gives access to the FAST INSERTS
pop-up. Each selection can have a pre-assigned input, output and
appropriate name. These are set up via the PREF (Preferences) GUI
described later in this chapter.
Click on the desired device name in the pop-up and its input and output
will be connected simultaneously. The I/O device names will be displayed
in the fourth and fifth fields and the actual device name will be displayed
in the seventh (lowest) scribble field. The name will also be displayed in
the Insert section of the MULTITRACK Panel in the dot character display.
Once actioned as a Fast Insert, the assignments to the other fields can be
edited or set up on an individual basis as described later.
Note:
The M/T GROUP OUTPUTS are always fed to MADI loops 1 and 2 but further
parallel assignments can be made as follows:
GROUP OUTPUT – Second field
The second field is used to select the destination for the M/T Group
outputs. Click on this for the pop-up displaying possible destinations.
Figure A shows analogue destinations (DACs). Click on the desired DAC
number to assign a Send. For a digital output, click on AES for the list of
digital destinations. Further pages of related pop-ups can be accessed by
clicking on " or ". Click on OFF to disable an output.
RANGE
A contiguous range of M/T Group outputs can be assigned simultaneously.
To assign a set of consecutive groups to a number of consecutive outputs,
channel M/T Groups 1-4 feeding DACs 5-8 as an example:
• Click on the second field of Channel 1 for the assignment pop-up shown
in Figure B.
• Click on RANGE and its characters turn white and the background red.
• Click on the lowest number of the DACs required, 5 in this example, and
it highlights red.
• Click on the highest number of the DACs required, 8 in this example, and
DACs 5-8 are assigned simultaneously to M/T Group Sends 1-4.
GROUP O/P WORD LENGTH – Third field left
The third field allows the M/T Group output word length to be set, if the
send is digital. Click on it to cycle through the word lengths 16 bit, 20 bit
and 24 bits.
Note:
The word length for the MADI output is set at the central Monitor Panel.