18
Save/Email/Recall (Setups, Screens, Data)
3 In the Save Trace and Setup Menu, press Format; then, turn the Entry
308
knob to select the type of file you want to save:
Setup (*.scp) — The oscilloscope's horizontal timebase, vertical
sensitivity, trigger mode, trigger level, measurements, cursors, and
math function settings that tell the oscilloscope how to make a
particular measurement. See
8-bit Bitmap image (*.bmp) — The complete screen image in a reduced
color (8- bit) bitmap format. See
page 310.
24-bit Bitmap image (*.bmp) — The complete screen image in a 24- bit
color bitmap format. See
page 310.
24-bit image (*.png) — The complete screen image in a 24- bit color PNG
format that uses lossless compression. Files are much smaller than
the BMP format. See
CSV data (*.csv) — This creates a file of comma- separated values of all
displayed channels and math waveforms. This format is suitable for
spreadsheet analysis. See
files"
on page 310.
ASCII XY data (*.csv) — This creates separate files of comma- separated
values for each displayed channel. This format is also suitable for
spreadsheets. See
page 310.
Binary data (*.bin) — This creates a binary file, with a header, and data
in the form of time and voltage pairs. This file is much smaller than
the ASCII XY data file. See
files"
on page 310.
Lister data (*.csv) — This is a CSV format file containing serial decode
row information with commas separating the columns. See
Lister data files"
Reference Waveform data (*.h5) — Saves waveform data in a format that
can be recalled to one of the oscilloscope's reference waveform
locations. See
"To save reference waveform files to a USB storage
device"
on page 314.
Multi Channel Waveform data (*.h5) — Saves multiple channels of
waveform data in a format that can be opened by the N8900A
InfiniiView oscilloscope analysis software. You can recall the first
Analog or Math channel from a multi channel waveform data file.
"To save setup files"
"To save BMP or PNG image files"
"To save BMP or PNG image files"
"To save BMP or PNG image files"
"To save CSV, ASCII XY, or BIN data
"To save CSV, ASCII XY, or BIN data files"
"To save CSV, ASCII XY, or BIN data
on page 313.
Agilent InfiniiVision 4000 X-Series Oscilloscopes User's Guide
on page 309.
on
on
on page 310.
on
"To save