HP Z800 - Workstation - 6 GB RAM Maintenance And Service Manual page 228

Hp z800 workstation maintenance and service guide
Hide thumbs Also See for Z800 - Workstation - 6 GB RAM:
Table of Contents

Advertisement

Table 6-8
Diagnostic lights and audible codes (continued)
Activity
Red Power LED blinks eight
times, once every second,
followed by a two-second
pause. Eight beeps.
Red Power LED blinks nine
times, once every second,
followed by a two-second
pause. Nine beeps.
216 Chapter 6 Diagnostics and troubleshooting
Possible cause
Invalid ROM based on bad
checksum.
System powers on but does
not start.
Recommended action
CAUTION:
Internal components might be powered even when the
workstation is off. To prevent damage, disconnect the workstation power
cord before you remove a component.
1.
Clear CMOS.
NOTE:
Refer to the Maintenance and Service Guide for the
workstation model for detailed information on clearing CMOS.
2.
Upgrade the ROM using SoftPaq, either from the hard drive, CD,
diskette, or USB removable device (for example., HP Drive Key).
See the ROM Flash section of the Maintenance and Service
Guide at http://www.hp.com/support/workstation_manuals. SoftPaq
is a self-extracting executable, which contains instructions for its
use, that enables you to upgrade the ROM. To download the Softpaq
executable, visit http://www.hp.com/go/workstationsupport.
3.
The problem might be on the system board. Contact HP for
assistance.
The problem might be on the system board. Contact HP for
assistance.
The problem might be in the CPU. Contact HP for assistance.
ENWW

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Z800

Table of Contents