Operator Panel Message
086 CONTROL 15V CHECK
SEE USERS MANUAL (continued)
087 PLATEN OPEN TIMEOUT
CLOSE PLATEN
Table 3. Message List
Explanation
On a coax interface, the forms
thickness lever has been open for
at least one minute. Load paper.
Corrective Action
12. Run a print test. If the message appears, do the power supply
operational check (page 258). If the power supply fails the check,
replace it. If it passes the check, Contact your DDS and Second
Level Support.
1. Close the forms thickness lever. Press STOP.
2. Run a print test. If a platen open or close platen message
appears, Power off and unplug the printer. Remove the paper
guide assembly or pedestal top cover. Disconnect connector
P107 from the controller board. Check continuity of the platen
interlock switch cable from P107 to the switch. Replace the platen
interlock switch assembly if it fails continuity test.
3. Check that the platen interlock switch is not loose.
4. Check and adjust the platen open belt. Replace the belt if it is
damaged.
5. Disconnect connector P106 from the controller board. Check the
resistance of connector P106/PLAT M. (Refer to the Main Wire
Harness Test Tables in Chapter 3.) Replace the platen open
motor if it fails the resistance test.
6. Check the shuttle for electrical shorts (page 252).
7. Plug in the printer and power it on. Run a print test. If the problem
reappears, the controller board or microcode is suspect. Do the
following:
8. Save the printer configuration values. (Refer to the User's
Manual .)
9. Clear NVRAM (page 237).
10. Download and install the latest code from IBM First (page 231).
Display Messages