Operator Panel Message
006 HOST SYSTEM
REQUEST ATTENTION
007 FM HEADER ERROR
008 HOLD PRINT TIMEOUT
PRESS START
009 INVALID KEY PRESS
010 PARAMETER ERROR
011 SCS COMMAND ERROR
Table 3. Message List
Explanation
Host attention message: the host
computer or printer controller
requires attention.
Applications software has violated
header format parameters.
Status message: the printer was
offline more than 10 minutes and
the "Intervention Required"
parameter is set to "Send to Host."
Attention message informing the
operator that the wrong key was
pressed.
The printer received an illegal
parameter value in the command
code.
The printer received an undefined
control character (hex 40) through
the coax/twinax interface.
Corrective Action
Not a printer problem.
Not a printer problem. Have the system administrator correct
applications data or configuration.
Press START to put the printer in the READY state.
No action required.
1. Press STOP to clear the fault. Press START to go to the READY
state.
2. Run the print job that generated the error message. If the
message appears, check the host data for invalid characters.
3. Ask the system operator to verify that the printer's Device ID is set
to the correct emulation with respect to the host configuration.
4. Run the print job that generated the error message. If the
message appears, go to Communications Failures, page 211.
1. The printer clears the error.
2. Run the print job that generated the error message. If the
message appears, verify that there are no invalid control codes in
the host data.
3. Ask the system operator to verify that the printer's Device ID is set
to the correct emulation with respect to the host configuration.
4. Run the print job that generated the error message. If the
message appears, go to Communications Failures, page 211.
Display Messages
47
Need help?
Do you have a question about the Infoprint 6500-v05 and is the answer not in the manual?
Questions and answers