How Calls Are Affected When Switchover Occurs; Requirements For Other System Components - Altigen MAXCS ACC 6.5 Administration Manual

Maxcs acc system
Table of Contents

Advertisement

The network of the active system disconnects, and Automatically assume control
when active system is not available is selected in the Redundancy dialog box of
the standby system (see Figure 2 on page 367).

How Calls Are Affected When Switchover Occurs

When system control switches from the active to the standby system, it affects calls in
the following ways:
A direct connected call is kept (except in the case of shutdown or restart), like
extension A calls extension B and is connected. All other calls are disconnected (for
example, conference calls; silent monitor, barge in and coaching calls; parked calls,
queued calls, and calls in music-on-hold; APC calls; paging). In voice mail, a
Zoomerang call is kept but you cannot go back to VM.
In those direct connected calls, if one or both sides uses an H.323 channel, it will be
reset after switching over. MAXCS 6.5 redundancy supports:
Analog Ext/Trk to Analog Ext/Trk
Analog Ext/Trk to T1/E1/PRI
Analog Ext/Trk to SIP Ext/Tie/Trunk
T1/E1/PRI to SIP Ext/Tie/Trunk
SIP Ext/Tie/Trunk to SIP Ext/Tie/Trunk
Mobile Ext to Analog Ext/Trk
Mobile Ext to T1/E1/PRI
Mobile Ext to SIP Ext/Tie/Trunk
The connected trunk and extension channel shows "in use" in the standby Softswitch
until it is disconnected.
CDR is dropped for all calls, including connected calls.
Recording stops.
After switching, channels and extensions that were connected still have busy status,
and a call to these channels or extensions will follow busy call handling rules.
If a SIP channel is involved in a call, and a resource channel in the local gateway is
allocated, the call will not be kept.
After switchover, disconnection is the only action available to calls that remained
connected. (Users cannot transfer, conference, park, start recording, and so on.)
If a connected call does not hang up within 30 minutes after switchover happens,
the call is reset by the standby server. The value of timeout can be changed in the
registry. The path is "HKEY_LOCAL_MACHINE\SOFTWARE\AltiGen Communications,
Inc.\AltiWare", and the key name is "RedundCallConnectTimeout". After changing
the timeout value, you must restart the server to apply the change.

Requirements for Other System Components

This section lists firmware and software requirements.
Chapter 26: Redundancy Configuration
MAXCS ACC 6.5 Administration Manual 365

Advertisement

Table of Contents
loading

This manual is also suitable for:

Max communication server acc 6.5

Table of Contents