To configure system options
This is the address of a smart mail relay host.
This applies if you are routing email to an
intermediate mail server.
This setting must be either a FQDN
Note:
or an IP Address in brackets.
[10.1.1.1]
Example:
This setting requires that all user sessions and
web presentations are handled by SSL
encrypted browser connections (HTTPS). If
you select this setting, you must also enable
port 443 in any firewall that is deployed
between an OmniTouch ACS application and
the users who access it through the internet.
All log files generated through ACS
Note:
can be retrieved through port 443 at
https://servername/admin/getlogs.html.
This determines whether conference URLs
(including those that are used for web
presentations) are protected (encrypted) by
SSL (HTTPS) or not encrypted by SSL
(HTTP). If you select HTTPS, ensure that
port 443 is open on any firewall that is
deployed between an OmniTouch ACS
application and the internet.
This is the period of time of user inactivity
before a user's browser session with an
OmniTouch ACS application is automatically
terminated. Because a session can remain
open during a conference call, and because
that session may be used for call control at
some point well after that call has started, this
should be set to long enough that users won't
be logged out during a call, but short enough
that an open session does not constitute a
potential security issue. This defaults to 8
hours.
If a user checks the "Automatically log me in
on this computer" box on that user's sign-in
page, this timeout will not apply to that user
on that computer.