066: Cmp-Par.4Eq
(Compressor – Parametric 4-Band EQ)
This  effect  combines  a  mono‐type  compressor  and  a 
four‐band  parametric  equalizer.  You  can  change  the 
order of the effect connection.
Wet: Mono In - Mono Out / Dry: Stereo In - Stereo Out
Left
Compressor
+
Comp
Output Level
Right
Envelope - Control
[C] Sensitivity
a
Sets the sensitivity
[C] Attack
Table , "Sets the attack level," on page 176
b
Output Level
Sets the compressor output level
[E] Trim
c
Sets the parametric EQ input level
[E] Band1 Cutoff [Hz]
Sets the center frequency of Band 1
Q
d
Sets the bandwidth of Band 1
Gain [dB]
Sets the gain of Band 1
[E] Band2 Cutoff [Hz]
Sets the center frequency of Band 2
Q
e
Sets the bandwidth of Band 2
Gain [dB]
Sets the gain of Band 2
[E] Band3 Cutoff [Hz]
Sets the center frequency for Band 3
Q
f
Sets the bandwidth of Band 3
Gain [dB]
Sets the gain of Band 3
[E] Band4 Cutoff [Hz]
Sets the center frequency for Band 4
Q
g
Sets the bandwidth of Band 4
Gain [dB]
Sets the gain of Band 4
Routing
h
Switches the order of the compressor and parametric EQ connection
Wet/Dry
Table , "Sets the balance between the effect and dry sounds," on page 175
Src
i
Table , "Selects the modulation source of the effect balance," on page 175
Amt
Table , "Sets the modulation amount of the effect bal-
ance," on page 175
Wet / Dry
Routing
Parametric 4Band EQ
Trim
Wet / Dry
1...100
Fx:002
1...100
Fx:002
0...100
Fx:002
0...100
20...1.00kHz
0.5...10.0
Fx:006
–18...+18dB
50...5.00kHz
0.5...10.0
Fx:006
–18...+18dB
300...10.00kHz
0.5...10.0
Fx:006
–18...+18dB
500...20.00kHz
0.5...10.0
Fx:006
–18...+18dB
CMP  PEQ, PEQ  CMP
Dry, 1:99...99:1, Wet
Off...Tempo
–100...+100
067: Cmp-ChorFlg
(Compressor – Chorus/Flanger)
This  effect  combines  a  mono‐type  compressor  and  a 
chorus/flanger.  You  can  change  the  order  of  the  effect 
connection.
Wet: Mono In - Stereo Out / Dry: Stereo In - Stereo Out
Left
Compressor
EQ Trim
LEQ HEQ
+
Comp
Output Level
Right
Envelope - Control
[C] Sensitivity
a
Sets the sensitivity
[C] Attack
Table , "Sets the attack level," on page 176
b
Output Level
Sets the compressor output level
[C] EQ Trim
c
Table , "Sets the EQ input level," on page 176
[C] Pre LEQ Gain [dB]
Table , "Sets the gain of Low EQ," on page 176
d
Pre HEQ Gain [dB]
Table , "Sets the gain of High EQ," on page 176
[F] Delay Time [msec]
e
Sets the delay time
[F] LFO Frequency [Hz]
Sets the LFO speed
f
LFO Waveform
Selects LFO Waveform
[F] Depth
Sets the depth of LFO modulation
g
Feedback
Sets the feedback amount
[F] Cho/Flng Wet/Dry
Sets the effect balance of the chorus/flanger
h
Output Mode
Selects the output mode for the chorus/flanger
Routing
i
Switches the order of the compressor and chorus/flanger connection
Wet/Dry
Table , "Sets the balance between the effect and dry sounds," on page 175
Src
j
Table , "Selects the modulation source of the effect balance," on page 175
Amt
Table , "Sets the modulation amount of the effect bal-
ance," on page 175
h: Output Mode, i: Routing
When Wet Invert is selected, the right channel phase of the
chorus/flanger effect sound is inverted. This creates pseudo-
stereo effects and adds spread.
However, if a mono-input type effect is connected after this
effect, the left and right sounds may cancel each other, elimi-
nating the chorus/flanger effects.
When "Routing" is set to FLNGCMP, "Output Mode" will be
set to Normal.
Effects
Mono – Mono Chain
Wet / Dry
Routing
Chorus/Flanger
Chorus/Flanger
Normal
+
Output Mode
Wet Invert
Feedback
Cho/Flng Wet / Dry
Wet / Dry
LFO: Tri / Sine
1...100
Fx:002
1...100
Fx:002
0...100
Fx:002
0...100
–15...+15dB
–15...+15dB
0.0...50.0msec
0.02...20.00Hz
Triangle, Sine
0...100
–100...+100
Fx:020
–Wet...–2:98, Dry, 2:98...Wet
Fx:010, 020
Normal, Wet Invert
CMP  FLNG, FLNG  CMP
Dry, 1:99...99:1, Wet
Off...Tempo
–100...+100