Error code
Display
E052
E061
E204
E220
E221
E302
E305
E306
E307
Description of error
Thread breakage detection
error
When thread breakage is
detected.
Memory switch data error
Memory switch data is
broken or revision is old.
USB connection error
With the number of times
of sewing has reached 10
or more, with a USB device
connected to the sewing
machine
Grease-up warning
At the time of operation of
100 million stitches
"#-1-12
→ Refer to
Replenishing the
designated places with
grease"
p.122.
Grease-up error
At the time of operation of
120 million stitches
The sewing machine is put
in the sewing-impossible
status. It is possible to
clear with memoryswitch
.
"#-1-12
→ Refer to
Replenishing the
designated places with
grease" p.122.
Head tilt confirmation
When head tilt sensor is
OFF.
Cloth cutting knife
position error
Cloth cutting knife is in the
regular position.
Thread clamp position
error
Thread clamp unit is not in
the regular position.
External input command
time out error
Input is not performed for a
fixed period of time with the
external input command of
vector data.
Display message
– 106 –
Place of
How to recover
recovery
Possible
Step
to re-start
screen
after reset.
Turn OFF
the power
Possible
Sewing
to re-start
screen
after reset.
Possible
Data
to re-start
input
after reset.
screen
Possible
Data
to re-start
input
after reset.
screen
Possible
Previous
to re-start
screen
after reset.
Turn OFF
Data
the power
input
screen
Turn OFF
the power
Possible
Data
to re-start
input
after reset.
screen

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ip-420Ams-210en

Table of Contents