JUKI AMS-210EN/IP-420 Instruction Manual page 109

Hide thumbs Also See for AMS-210EN/IP-420:
Table of Contents

Advertisement

Error code
Display
E024
E027
E028
E029
E030
E031
E032
E040
E043
E045
E050
Description of error
Pattern data size over
Memory size is over.
Read error
Data read from server
cannot be performed.
Write error
Data write from server
cannot be performed.
Media slot release error
Lid of media slot is open.
Needle bar position
missing error
Needle bar is not in the
predetermined position.
Air pressure drop
Air pressure is dropped.
File interchanging error
File cannot be read.
Sewing area over
Enlarging error
Sewing pitch exceeds Max.
pitch.
Pattern data error
Stop switch
When stop switch is pressed
during machine running.
Display message
– 105 –
Place of
How to recover
recovery
Possible
Data
to re-start
input
after reset.
screen
Possible
Previous
to re-start
screen
after reset.
Possible
Previous
to re-start
screen
after reset.
Possible
Previous
to re-start
screen
after reset.
Turn hand
Data
pulley to
input
bring needle
screen
bar to its
predetermined
position.
Possible
Data
to re-start
input
after reset.
screen
Possible
Data
to re-start
input
after reset.
screen
Possible
Sewing
to re-start
screen
after reset.
Possible
Data
to re-start
input
after reset.
screen
Possible
Data
to re-start
input
after reset.
screen
Possible
Step
to re-start
screen
after reset.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ip-420Ams-210en