Complex Configurations

It is possible to design systems that don't fall into any of the above scenarios, but not
all combinations of inputs on sub walls are possible. A system cabled for such a
complex configuration may or may not be able to also have some of the simpler
configurations.
Scenario 7: Multiple Large Sub Walls
The previous scenario was restricted such that only one sub wall in a Runco
WindowWall could be larger than a single Quad Input Manager Module. If you desire
more than one sub wall that is larger than four displays, there are certain restrictions.
You must cable the loop connections sequentially among the quad modules that
make up each sub wall. Since a sub wall that spans more than one Quad Input
Manager Module module uses the external loop, a sub wall is restricted to using
inputs from only the first Quad Input Manager Module in the loop through chain.
Quad Module Route A
Switch 1
Loop
Switch 2
Loop
Switch 3
Loop
Switch 4
Loop
Internal Loop
Digital 1
X External Loop
Digital 2
Use Loop
External
Quad Module Route B
Switch 1
Loop
Switch 2
Loop
Switch 3
Loop
Switch 4
Loop
Internal Loop
Digital 3
External Loop
Digital 3
Use Loop
External
Quad Module Route C
Switch 1
Loop
Switch 2
Loop
Switch 3
Loop
Switch 4
Loop
Internal Loop
Digital 1
X External Loop
Dual Link In
Use Loop
External
Quad Module Route D
Switch 1
Loop
Switch 2
Loop
Switch 3
Loop
Digital 1
Switch 4
Loop
Source 1
Internal Loop
Digital 1
X External Loop
Dual Link In
Use Loop
External
Digital 1
Source 4
Digital 1
Source 7
Digital 1
Source 7
Note:
each sub wall is limited to four sources.
A1
Wall Width
2
Wall Height
4
Unit Row
1
Unit Column
1
X Wall Mode
X Wall Mode
A3
Wall Width
2
Wall Height
4
Unit Row
2
Unit Column
1
X Wall Mode
X Wall Mode
C1
Wall Width
2
Wall Height
4
Unit Row
3
Unit Column
1
X Wall Mode
X Wall Mode
C3
Wall Width
2
Wall Height
4
Unit Row
4
Unit Column
1
X Wall Mode
X Wall Mode
Dual Link In
A
Loop Out
Digital 2
Digital 3 Digital 4
Source 2
Source 3
Source 4
Dual Link In
B
Loop Out
Digital 2
Digital 3 Digital 4
Source 5
Source 6
Source 6
Dual Link In
C
Digital 2
Digital 3 Digital 4
Loop Out
Source 8
Source 9
Source 9
Dual Link In
D
Digital 2
Digital 3 Digital 4
Loop Out
Source 8
Source 8
Source 8
4 x 4 Runco WindowWall with two 4 x 2 sub walls. One Big Picture is also available, but
Runco WindowWall Installation Guide
A2
Wall Width
2
Wall Width
Wall Height
4
Wall Height
Unit Row
1
Unit Row
Unit Column
2
Unit Column
X Wall Mode
A4
Wall Width
2
Wall Width
Wall Height
4
Wall Height
Unit Row
2
Unit Row
Unit Column
2
Unit Column
X Wall Mode
C2
Wall Width
2
Wall Width
Wall Height
4
Wall Height
Unit Row
3
Unit Row
Unit Column
2
Unit Column
X Wall Mode
C4
Wall Width
2
Wall Width
Wall Height
4
Wall Height
Unit Row
4
Unit Row
Unit Column
2
Unit Column 1
X Wall Mode
Note the cabling difference. A must loop out to C. B must loop out to D
Any Source from A can be spread on the left half. Any source from B can be spread
on the right half
Configuration Scenarios
B1
2
Wall Width
2
4
Wall Height
4
1
Unit Row
1
2
Unit Column 2
X Wall Mode
B3
2
Wall Width
2
4
Wall Height
4
2
Unit Row
2
1
Unit Column
2
X Wall Mode
D1
2
Wall Width
2
4
Wall Height
4
3
Unit Row
3
1
Unit Column
2
X Wall Mode
D3
2
Wall Width
2
4
Wall Height
4
4
Unit Row
4
Unit Column
2
X Wall Mode
B2
B3
D2
D4