Recommended Usage

Normal Use Thermal Guidelines

Normal use of the LCD tile, Quad Input Manager Module and power supply module
are defined as operating in the open air to prevent heat buildup, and without direct
or indirect heat sources such as lighting fixtures, heating ducts, or direct sunlight that
can cause the modules to experience high operating temperatures. For all modules,
do not block fans or ventilation openings. At 2000 meters or below, the maximum
ambient operating temperature for the LCD tile cannot be above 35º C nor below the
minimum ambient operating temperature of 0º C. For the Quad Input Manager
Module and power supply module, the maximum ambient operating temperature
cannot be above 45º C nor below the minimum ambient operating temperature of 0º
C. If one of these conditions exists, it is up to the installer to ensure that module
placement is changed, thermal shielding is provided and/or additional ventilation is
provided to keep the display within its nominal operating parameters.
Cooling Requirements
For optimal performance, active cooling by the installer should be planned for when
the ambient temperature at the top of the wall is predicted to be above the specified
ambient temperature for the tile. Cooling may be done behind the displays and
depending on the wall configuration, it may be helpful to place air ducts (AC) at
every third display tall.