Diagnostics

Most of the submenus available from the
regular basis. Examples of these menus can be found in "On-Screen Menus" on
page 119.
To check status information for the system or to see usage information, use the
STATUS

Checking Unit Status

The
and the power supply module. This can be a helpful troubleshooting tool if you are
having operational issues with one of the system components.
Un i t Stat us A 1
MX 46L
01 0- 116 8
LC D
Q ua d Mod ul e
P o w e r S u p pl y
LCD
Indicates the current internal temperature at one point inside the LCD. This is not the
highest or the lowest temperature of the LCD, nor an indicator of ambient
temperatures. Also shows if the backlight temperature is operating within a normal
range. If the voltage is below 22, there is an issue with power to the LCD. This will
mostly likely be an issue with cable length or quality of the cable between the power
supply module and the LCD tile.
Quad Module
Indicates the current internal temperature at one point inside the Quad Input
Manager Module. This is not the highest or the lowest temperature of the LCD, nor
an indicator of ambient temperatures. Also shows whether or not the fan inside in
the Quad Input Manager Module is operating.
and
menus, which are explained in the following sections.
HOURS
menu shows information for the LCD, Quad Input Manager Module
UNIT STATUS
R ev 02
Tem p er at u re
B ac kli gh t
Vo l tag e
Tem p er at u re
F an F a ile d
PS 1
PS 2
PS 3
PS 4
R ed u nd a nt
Runco WindowWall Installation Guide
DIAGNOSTICS
1 36 6 x 7 68
25 ° C
O K
24
3 1 ° C
O K
F a n
O n
O K
O K
O K
O K
menu are not used on a