Troubleshooting - Runco WindowWall Installation Manual

Display wall
Hide thumbs Also See for WindowWall:
Table of Contents

Advertisement

Troubleshooting

Below is a troubleshooting table of some common issues you might encounter when
installing or running your Runco WindowWall display wall.
What to look for
Solid Green LED next
to Video connection
on LCD interface board
(on the back of the
display tile)
Blinking Green LED
next to Comm
connection on LCD
interface board (on the
back of the display
tile).
Power LED on front
panel of the Quad
Module is green. One
address LED is lit.
Blinking RS-485 light
on all Quad Input
Manager Modules
except A.
Green LED in Out
Column for the display
tile (LCD).
What you know if you
see it
Video connection is
good.
Comm connection is
good.
Front panel is connected
and working properly.
Power is good to the
Quad Input Manager
Module.
RS-485 connections are
good.
Video connection to
display tile is good
Comm connection to
display tile is good
'A' Quad Module is
powered on and cabled
to this one via RS-485
All Quad Input Manager
Modules have unique
addresses.
Runco WindowWall Installation Guide
What to look for if you don't see it
Check power connections to display tile and
Quad Input Manager Module. Make sure
Video and Comm connections are not
swapped.
Check power connections to display tile and
Quad Input Manager Module. Make sure
Video and Comm connections are not
swapped.
Check power to Quad Input Manager Module.
If you see more than one address LED lit (the
ones on the circle) the system is doing an
automatic update. Wait up to 20 minutes for it
to complete. Do not turn off power during
this time.
You must have one and only one 'A' Quad
Module.
If the LED is red, there is Comm connection
but not video connection.
It can take up to a minute for this LED to
reflect the state of the system—you may need
to wait if you have just turned on or changed
connections.