Operation Commands for Runco WindowWall ......19 Troubleshooting Serial Connections..........51 Index ......................57 You should already know how to operate the Runco WindowWall with the remote control and how to read the menus. See the Runco WindowWall Installation Guide for more information.
Connecting RS232 Communication RS232 control is not necessary for operation, but is a convenient way to control tiles from a computer at a distance. If your installation will not use RS232 control, skip this section. Everything you can do with the remote, you can do with RS232 commands. Plus, you can send inquiries to the tiles and find out the current settings and values.
Page 3
RS485 In connector. Connect this first tile’s RS485 Out connector to the next tile’s RS485 In connector. For more information about configuring RS232 communications, see the WindowWall Installation Manual. Connect this to Quad Input Manager Module A only - make sure you don’t connect to other Quad Input...
Page 4
How to Form Commands How to Form Commands Basic Rules • RS232 commands consist of a string of ascii characters. • All numeric values are decimal; you do not need to use hex or binary digits in the commands. • Spaces or tabs may be used in the commands to separate the parts and make them easier for humans to read.
A few commands have a ‘target. ’ For example, to adjust white balance, you must state which color to change: red, green, blue, or all. Or to determine whether a memory slot is empty, you must target the memory slot number. The target is always in (parentheses). RS232 Control...
Page 6
The command line must always end with a carriage return character, noted in the exam- ples above as [CR]. The Runco WindowWall will not act on the command unless the last character is a carriage return character (ascii hex value: 0D).
Page 7
You don’t know where the cursor was at the start. Sample String Commands Command Explanation Example st A1 revision ?[CR] What is the revision level of tile A1? RS232 Control...
If the Target column has anything in it, the command must use one (and only one) of the targets, and it must be in parentheses. Use either the ascii text or the Target Number. These are equivalent commands: opa2 center.point (red) ? [CR] opa21110(0)? [CR] RS232 Control...
Page 9
(or the Target, if it has one) Note: Any word or character or phrase that appears between [square brackets] is for information or clarification only. It is not sent to the tile or received from it. RS232 Control...
Page 10
The tile received the op A1 ascii.response = symbolic [CR] OPA1ASCII.RESPONSE=SYMBOLIC command and has set the response type to symbolic and replies will be ascii characters The current test pattern is op A1 pattern ? [CR] OPA1PATTERN=BLACK black. RS232 Control...
Page 11
The current test pattern is op A1 pattern ? [CR] black. Note: Replies are always in ALL CAPS, regardless of how the query was sent. RS232 Control...
“pressed” in this manner by using the name on the remote. This picture shows the command for each named key: Note: Keep in mind that you need to point the remote towards where the IR sensor is mounted. RS232 Control...
Page 13
Bring up the on-screen menus. Return to the previous menu. Press to select a menu option. Move highlight to the top line of the menu. Arrow keys move the highlight around on the menu to select the option you want. RS232 Control...
Page 14
R1Ø picture save misc R3Ø source monitor wall balance menu prev enter R6Ø left right R8Ø down Note: Although they don’t exist on the remote, there are two more key commands that can be used: target.up and target.down. RS232 Control...
This saves all the current settings into memory op A1 slot.action (save) [CR] slot #4 with the default memory name. ▲ This sets the memory slot to #5, which is empty. op A1 slot.target = 4 [CR] ▲ RS232 Control...
Page 16
A1 slot.recall.target = 5 [CR] ▲ This recalls slot #6 because the target was op A1 slot.action (recall) [CR] set to #6 in the previous command. ▲ Recalls settings from memory slot #1. op A1 slot.action (recall) [CR] ▲ RS232 Control...
Page 17
The command line must always end with a carriage return character, noted in the exam- ples above as [CR]. The Runco WindowWall will not act on the command unless the last character is a carriage return character (ascii hex value: 0D).
Page 18
Remember: tiles only respond when they are individually addressed. If you want to know a status or a value in six different tiles, you must ask the question six times, and you must wait for the response from each tile before sending the question to the next one. RS232 Control...
“op”, except those marked with [ST] which are String commands. For String commands, use the form “ST -- build.date ?” without the quotes, and substitute the unit ID for the -- . There is no target for string commands. Operation Commands for Runco WindowWall Command Value...
Page 20
Operation Commands for Runco WindowWall Command Value types allowed Operation (Target) If numbers listed first, use (Use only Target or Target number numbers only. Data in Notes one symbol) String [ST ] must be in parentheses. [square brackets] is for information only.
Page 21
Operation Commands for Runco WindowWall Command Value types allowed Operation (Target) If numbers listed first, use (Use only Target or Target number numbers only. Data in Notes one symbol) String [ST ] must be in parentheses. [square brackets] is for information only.
Page 22
Operation Commands for Runco WindowWall Command Value types allowed Operation (Target) If numbers listed first, use (Use only Target or Target number numbers only. Data in Notes one symbol) String [ST ] must be in parentheses. [square brackets] is for information only.
Page 23
Operation Commands for Runco WindowWall Command Value types allowed Operation (Target) If numbers listed first, use (Use only Target or Target number numbers only. Data in Notes one symbol) String [ST ] must be in parentheses. [square brackets] is for information only.
Page 24
Operation Commands for Runco WindowWall Command Value types allowed Operation (Target) If numbers listed first, use (Use only Target or Target number numbers only. Data in Notes one symbol) String [ST ] must be in parentheses. [square brackets] is for information only.
Page 25
Operation Commands for Runco WindowWall Command Value types allowed Operation (Target) If numbers listed first, use (Use only Target or Target number numbers only. Data in Notes one symbol) String [ST ] must be in parentheses. [square brackets] is for information only.
Page 26
Operation Commands for Runco WindowWall Command Value types allowed Operation (Target) If numbers listed first, use (Use only Target or Target number numbers only. Data in Notes one symbol) String [ST ] must be in parentheses. [square brackets] is for information only.
Page 27
Operation Commands for Runco WindowWall Command Value types allowed Operation (Target) If numbers listed first, use (Use only Target or Target number numbers only. Data in Notes one symbol) String [ST ] must be in parentheses. [square brackets] is for information only.
Page 28
Operation Commands for Runco WindowWall Command Value types allowed Operation (Target) If numbers listed first, use (Use only Target or Target number numbers only. Data in Notes one symbol) String [ST ] must be in parentheses. [square brackets] is for information only.
Page 29
Operation Commands for Runco WindowWall Command Value types allowed Operation (Target) If numbers listed first, use (Use only Target or Target number numbers only. Data in Notes one symbol) String [ST ] must be in parentheses. [square brackets] is for information only.
Page 30
Operation Commands for Runco WindowWall Command Value types allowed Operation (Target) If numbers listed first, use (Use only Target or Target number numbers only. Data in Notes one symbol) String [ST ] must be in parentheses. [square brackets] is for information only.
Page 31
Operation Commands for Runco WindowWall Command Value types allowed Operation (Target) If numbers listed first, use (Use only Target or Target number numbers only. Data in Notes one symbol) String [ST ] must be in parentheses. [square brackets] is for information only.
Page 32
Operation Commands for Runco WindowWall Command Value types allowed Operation (Target) If numbers listed first, use (Use only Target or Target number numbers only. Data in Notes one symbol) String [ST ] must be in parentheses. [square brackets] is for information only.
Page 33
Operation Commands for Runco WindowWall Command Value types allowed Operation (Target) If numbers listed first, use (Use only Target or Target number numbers only. Data in Notes one symbol) String [ST ] must be in parentheses. [square brackets] is for information only.
Page 34
Operation Commands for Runco WindowWall Command Value types allowed Operation (Target) If numbers listed first, use (Use only Target or Target number numbers only. Data in Notes one symbol) String [ST ] must be in parentheses. [square brackets] is for information only.
Page 35
Operation Commands for Runco WindowWall Command Value types allowed Operation (Target) If numbers listed first, use (Use only Target or Target number numbers only. Data in Notes one symbol) String [ST ] must be in parentheses. [square brackets] is for information only.
Page 36
Operation Commands for Runco WindowWall Command Value types allowed Operation (Target) If numbers listed first, use (Use only Target or Target number numbers only. Data in Notes one symbol) String [ST ] must be in parentheses. [square brackets] is for information only.
Page 37
Operation Commands for Runco WindowWall Command Value types allowed Operation (Target) If numbers listed first, use (Use only Target or Target number numbers only. Data in Notes one symbol) String [ST ] must be in parentheses. [square brackets] is for information only.
Page 38
Operation Commands for Runco WindowWall Command Value types allowed Operation (Target) If numbers listed first, use (Use only Target or Target number numbers only. Data in Notes one symbol) String [ST ] must be in parentheses. [square brackets] is for information only.
Page 39
Operation Commands for Runco WindowWall Command Value types allowed Operation (Target) If numbers listed first, use (Use only Target or Target number numbers only. Data in Notes one symbol) String [ST ] must be in parentheses. [square brackets] is for information only.
Page 40
Operation Commands for Runco WindowWall Command Value types allowed Operation (Target) If numbers listed first, use (Use only Target or Target number numbers only. Data in Notes one symbol) String [ST ] must be in parentheses. [square brackets] is for information only.
Page 41
Operation Commands for Runco WindowWall Command Value types allowed Operation (Target) If numbers listed first, use (Use only Target or Target number numbers only. Data in Notes one symbol) String [ST ] must be in parentheses. [square brackets] is for information only.
Page 42
Operation Commands for Runco WindowWall Command Value types allowed Operation (Target) If numbers listed first, use (Use only Target or Target number numbers only. Data in Notes one symbol) String [ST ] must be in parentheses. [square brackets] is for information only.
Page 43
Operation Commands for Runco WindowWall Command Value types allowed Operation (Target) If numbers listed first, use (Use only Target or Target number numbers only. Data in Notes one symbol) String [ST ] must be in parentheses. [square brackets] is for information only.
Page 44
Operation Commands for Runco WindowWall Command Value types allowed Operation (Target) If numbers listed first, use (Use only Target or Target number numbers only. Data in Notes one symbol) String [ST ] must be in parentheses. [square brackets] is for information only.
Page 45
Operation Commands for Runco WindowWall Command Value types allowed Operation (Target) If numbers listed first, use (Use only Target or Target number numbers only. Data in Notes one symbol) String [ST ] must be in parentheses. [square brackets] is for information only.
Page 46
Operation Commands for Runco WindowWall Command Value types allowed Operation (Target) If numbers listed first, use (Use only Target or Target number numbers only. Data in Notes one symbol) String [ST ] must be in parentheses. [square brackets] is for information only.
Page 47
Operation Commands for Runco WindowWall Command Value types allowed Operation (Target) If numbers listed first, use (Use only Target or Target number numbers only. Data in Notes one symbol) String [ST ] must be in parentheses. [square brackets] is for information only.
Page 48
Operation Commands for Runco WindowWall Command Value types allowed Operation (Target) If numbers listed first, use (Use only Target or Target number numbers only. Data in Notes one symbol) String [ST ] must be in parentheses. [square brackets] is for information only.
Page 49
Operation Commands for Runco WindowWall Command Value types allowed Operation (Target) If numbers listed first, use (Use only Target or Target number numbers only. Data in Notes one symbol) String [ST ] must be in parentheses. [square brackets] is for information only.
Page 50
Operation Commands for Runco WindowWall Command Value types allowed Operation (Target) If numbers listed first, use (Use only Target or Target number numbers only. Data in Notes one symbol) String [ST ] must be in parentheses. [square brackets] is for information only.
53 as necessary. Setup Connect the RS232 cable from the computer to the RS232 In connector of Quad Input Manager Module A. Connect the out connector of that tile, to the In connector of the next tile and so on until all tiles are connected.
Page 52
For example, you can't set the brightness to 1000. If it sends an ERR, it didn't understand the command. Perhaps it is spelled wrong, or you are trying a command that is not valid on this product. RS232 Control...
Page 53
Check that the program is using the correct serial port. Check that the cable is connected to the RS232 In connection on tile A (not on the RS485 connector). RS232 Control...
Page 54
Input Manager Modules. If a module is bad, it could prevent any tiles from getting the message. If you suspect a bad module, get a small group working and then add tiles to the chain one at a time. RS232 Control...
Page 55
Troubleshooting Serial Connections Response From Individual Tiles Open the RS232 Serial Port Status menu on all tiles. Send a query command from the host to an individual tile. Do you see your query on the bottom Go to troubleshooting a global line of the menu of command chart.
Page 56
Troubleshooting Serial Connections RS232 Control...
Page 58
16398 dkgreen 16399 dkred 16400 bottom zoom 16401 brightness 16402 build date 16403 bytes received, number of 16404 bytes sent, number of 16436 16902 17420 17421 cable 17422 equalization 17426 Celsius temperature 17438 center pixel, value of RS232 Control...
IR wall mode blue display power, on/off green dkblue border color dkgreen border color gamma dkred border color go to top of menu gray balance in clipboard green border color gain offset RS232 Control...
Page 60
WindowWall tile runtime position of WindowWall system size of WindowWall mode WindowWall tile exists wall, enable/disable horizontal resolution of position quad status status name letter, memory (slot.name.letter) vertical resolution name, product vertical resolution of native frequency voltage NTSC RS232 Control...
Page 61
LCD hours, high of WindowWall layout hours, low vertical hours, reset power minutes tile on/off power on/off power supply status preferred.source.detection saturation product save name color balance values to clipboard type memory slot ps status slot name RS232 Control...
Page 62
LCD slot.name.save uart symbolic response sync type wall system column hours reset height of hours, high justify hours, low mode, enable/disable minutes status width of taller aspect ratio RS232 Control...
Page 63
WindowWall layout layout module layout module exists layout of tile layout position layout size quick configure route module route output route switch YPbPr colorspace reset zoom bottom height left side right side top side width RS232 Control...