Runco WindowWall Installation Manual page 51

Display wall
Hide thumbs Also See for WindowWall:
Table of Contents

Advertisement

Make sure the Quad Input Manager Module and the power supply module are
7
turned on. Turn on the LCD tile to make sure the data and video cables are
feeding information to the LCD tile. The data information is flowing correctly if
you see a green light flashing next to the COM connector. The video information
is flowing correctly if you see solid green light next to the VIDEO connector. If you
have accidentally reversed these two cables, you will not see green lights at all.
Verify that the LCD tile is working by putting up a gray scale test pattern. If you
8
see vertical streaks in the pattern, you will need to change the cable equalization
(press
once on the remote) until it disappears. For more information about
MISC
cable equalization, see "Cable Equalization" on page 66.
Slide the horizontal support bar on the back of the LCD up over the notch and
9
down into position.
Note:
If the display is not seated properly, make sure the x-axis and z-axis adjusters are
seated in the correct positions.
Verify that the position sensors are working by displaying the on-screen menus
10
on the LCD. The first LCD on the left in the row should always show the display ID
of 1:1. As you build the row out, the left of the two numbers on each LCD should
show an incremental number. In the example below, you would expect to see 1
in the far left LCD, 2 in the next one, etc. Each number must also be unique. If you
see a duplicate number or no information at all, check your cabling to make sure
everything is properly connected and all of your modules are turned on.
1:1
Runco WindowWall Installation Guide
Slide over notch
and down...
...and into position
2:1
3:1
Installing LCD Tiles
37

Advertisement

Table of Contents
loading

Table of Contents