Source Routing
The
QUICK CONFIGURE QUAD
configure this scenario. Use Quick Configure Quad 1 & 3.
Wall Settings
By choosing the Quick Configure, the system will configure each LCD automatically.
Because the settings are different for each display, the system must send many
commands to each LCD. Quick Configure Quad takes a bit longer to respond than
other Quick Configure settings.
Scenario 6: Multiple Sub Walls
It is possible to have more than one sub wall at one time on a Runco WindowWall if
certain rules are followed:
• One sub wall can be any size and use any input. This sub wall will use the
External Loop.
• All the other sub walls must fit within a single Quad Input Manager Module.
This means they will be 2 x 2 or smaller.
Quad Module Route A
Switch 1
Digital 1
Switch 2
Loop
Switch 3
Loop
Switch 4
Loop
Internal Loop
Digital 1
O Wall Mode
X External Loop
Dual Link In
Use Loop
External
Quad Module Route B
Switch 1
Loop
Switch 2
Loop
Switch 3
Loop
X Wall Mode
Switch 4
Loop
X Internal Loop
Digital 3
External Loop
Dual Link In
Use Loop
Internal
Quad Module Route C
Switch 1
Loop
X Wall Mode
Switch 2
Loop
Switch 3
Loop
Switch 4
Digital 4
Internal Loop
Digital 1
X External Loop
Dual Link In
Use Loop
External
Quad Module Route D
X Wall Mode
Switch 1
Loop
Switch 2
Loop
Switch 3
Digital 3
Digital 1
Switch 4
Loop
Source 1
Internal Loop
Digital 1
X External Loop
Digital 1
Use Loop
External
Digital 1
Source 4
Digital 1
Source 7
Digital 1
Digital 2
Source 7
Note:
4 x 4 Runco WindowWall with one large and one small sub wall.
setting in the
A1
Wall Width
Wall Width
2
Wall Height
Wall Height
2
Unit Row
Unit Row
1
Unit Column
Unit Column
1
X Wall Mode
A3
Wall Width
Wall Width
4
Wall Height
Wall Height
4
Unit Row
Unit Row
2
Unit Column
Unit Column
1
X Wall Mode
C1
Wall Width
4
Wall Width
Wall Height
4
Wall Height
Unit Row
3
Unit Row
Unit Column
1
Unit Column
X Wall Mode
C3
Wall Width
4
Wall Width
Wall Height
4
Wall Height
Unit Row
4
Unit Row
Unit Column
1
Unit Column
O Wall Mode
Dual Link In
A
Loop Out
Digital 2
Digital 3 Digital 4
Source 2
Source 3
Source 4
Dual Link In
B
Loop Out
Digital 2
Digital 3 Digital 4
Source 5
Source 6
Source 6
Dual Link In
C
Loop Out
Digital 2
Digital 3 Digital 4
Source 8
Source 9
Source 9
Dual Link In
D
Loop Out
Digital 3 Digital 4
Source 8
Source 8
Source 8
Runco WindowWall Installation Guide
WALL CONFIGURATION
A2
B1
4
Wall Width
2
4
Wall Height
2
1
Unit Row
1
2
Unit Column
2
X Wall Mode
A4
B3
4
Wall Width
2
4
Wall Height
2
2
Unit Row
1
2
Unit Column
2
X Wall Mode
C2
D1
4
Wall Width
4
4
Wall Height
4
3
Unit Row
3
2
Unit Column
3
X Wall Mode
C4
D3
2
Wall Width
2
2
Wall Height
2
1
Unit Row
1
1
Unit Column
1
O Wall Mode
Configuration Scenarios
menu is used to
B2
Wall Width
2
Wall Height
2
Unit Row
1
Unit Column
2
X Wall Mode
B3
Wall Width
2
Wall Height
2
Unit Row
2
Unit Column
2
X Wall Mode
D2
Wall Width
4
Wall Height
4
Unit Row
3
Unit Column
4
X Wall Mode
D4
Wall Width
4
Wall Height
4
Unit Row
4
Unit Column
4
X Wall Mode
113