15 TROUBLESHOOTING
Related buffer memory
address
Axis 1 Axis 2 Axis 3 Axis 4
Same as error codes 515 to 516
Refer to Section 5.3
"List of positioning data"
Refer to Section 5.3
"List of positioning data"
and Section 5.4
"Block start data"
Set range
(Setting with sequence program)
<Positioning address/movement
amount>
• unit [mm] [pulse] [inch]
–2147483648 to 2147483647
(Unit [degree]) cannot be set.
<Arc address>
–2147483648 to 2147483647
Same as in error codes 504, 506.
• Correct the control system or parameter.
(Refer to Section 9.1.6, 9.2.20)
• Do not make setting at buffer memory address 1906
(use prohibited area).
Correct the sub address (arc address).
(Refer to Section 9.2.10)
Correct the end address (positioning address).
(Refer to Section 9.2.10)
Correct the center point address (arc address).
(Refer to Section 9.2.11)
Correct the positioning address.
(Refer to Section 9.2.16, 9.2.17, 9.2.18)
In the error history, check the axis where the error
other than this error occurred, and remove the error
factor. Correct the block start data and positioning data.
15 - 19