13 COMMON FUNCTIONS
Setting item
Cd.2 Parameter
initialization request
Refer to Section 5.7 "List of control data" for details on the setting details.
[4] Parameter initialization method
(1) Parameter initialization is carried out using the dedicated instruction "PINIT".
(Refer to Chapter 14 "Dedicated instructions" for details.)
(2) Parameter initialization can also be carried out by the writing of the data
shown in the table below to the buffer memory using the TO
command/intelligent function device.
The initialization of the parameter is executed at the time point the data is
written to the QD75 buffer memory.
Setting
value
1
Set "1" (parameter initialization request).
When the initialization is complete, "0" will be set in "
initialization request" by the QD75 automatically.
Setting details
13 - 4
MELSEC-Q
Buffer memory address
Axis
Axis
Axis
1
2
3
1901
Cd.2
Parameter
Axis
4