11 MANUAL CONTROL
Cd. 21 Manual pulse generator
enable flag (axis control data)
Manual pulse generator input
pulses
BUSY signal
Start complete signal
[X10, X11, X12, X13]
Md. 26 Axis operation status
Pulse output to an external
source (PULSE)
Positioning operation
Fig. 11.19 Manual pulse generator operation timing and processing times
Manual pulse generator operation timing and processing time
The following drawing shows details of the manual pulse generator operation
timing and processing time.
0
1
t1
[XC,XD,XE,XF]
The start complete signal does not turn ON in manual pulse generator operation.
Standing by
Normal timing times
t1
0 to 2.6
6.2 to 32
Delays may occur in the t1 timing time due to the operation status of other axes.
In manual pulse generator operation
t2
t2
t3
64 to 90
11 - 29
MELSEC-Q
0
t3
t4
Unit : ms
t4
28.4 to 57.6
Standing by