3 SPECIFICATIONS AND FUNCTIONS
Sub function
Step function
Skip function
M code output function
Teaching function
Target position change
function
Other functions
Command in-position
function
Acceleration/deceleration
process function
Continuous operation
interrupt function
Pre-reading start function
Deceleration start flag
function
Stop command processing
for deceleration stop
function
This function temporarily stops the operation to confirm the
positioning operation during debugging, etc.
The operation can be stopped at each "automatic deceleration"
or "positioning data".
This function stops (decelerates to a stop) the positioning being
executed when the skip signal is input, and carries out the next
positioning.
This function issues a command for a sub work (clamp or drill
stop, tool change, etc.) corresponding to the M code No.
(0 to 65535) that can be set for each positioning data.
This function stores the address positioned with manual control
into the positioning address having the designated positioning
Cd.39
data No. (
).
This function changes the target position during positioning.
Position and speed can be changed simultaneously.
At each automatic deceleration, this function calculates the
remaining distance for the QD75 to reach the positioning stop
position. When the value is less than the set value, the
"command in-position flag" is set to "1".
When using another auxiliary work before ending the control,
use this function as a trigger for the sub work.
This function adjusts the control acceleration/deceleration.
This function interrupts continuous operation. When this
request is accepted, the operation stops when the execution of
the current positioning data is completed.
This function shortens the virtual start time.
Function that turns ON the flag when the constant speed status
or acceleration status switches to the deceleration status during
position control, whose operation pattern is "Positioning
complete", to make the stop timing known.
Function that selects a deceleration curve when a stop cause
occurs during deceleration stop processing to speed 0.
3 - 9
Details
MELSEC-Q
Reference
section
12.7.1
12.7.2
12.7.3
12.7.4
12.7.5
12.7.6
12.7.7
6.5.4
12.7.8
12.7.9
12.7.10

Advertisement