Restrictions For Installing Monitors; Monitoring; Table 73 Number Of Logical Switches That Support Performance Monitors - HP StoreFabric SN6500B Administrator's Manual

Fabric os administrator's guide, 7.1.0 (53-1002745-02, march 2013)
Hide thumbs Also See for StoreFabric SN6500B:
Table of Contents

Advertisement

20
Advanced Performance Monitoring overview

Restrictions for installing monitors

Virtual Fabrics considerations for Advanced Performance Monitoring
In a fabric with Virtual Fabrics enabled, the number of logical switches that can be configured with
monitors is restricted.
platform, the maximum number of logical switches that can support performance monitors.
TABLE 73
Platform
Brocade DCX
Brocade DCX-4S
Brocade 8510 family
Brocade 6510
Brocade 6520
Brocade 5100
Brocade VA-40FC
Brocade 5300
Each logical switch can have its own set of performance monitors. The installation of monitors is
restricted to the ports that are present in the respective logical switch.
If a port is moved from one logical switch to another, the behavior of monitors installed on that port
is as follows:
500
Advanced Performance Monitoring is not supported on VE_Ports and EX_Ports. If you issue
commands for any Advanced Performance Monitoring on VE_Ports or EX_Ports, you will receive
error messages.
For the Brocade 8000, Advanced Performance Monitoring is supported only on the FC ports
and not on the CEE ports.
All monitor types are allowed only on physical ports.
Top Talker monitors and EE monitors on E_Ports should be installed only in the ingress
direction.
Table 73
Number of logical switches that support performance monitors
Maximum number of logical switches supported
Top Talker monitors and EE monitors are supported on the default logical switch, the base
switch, and user-defined logical switches.
Frame monitors are not supported on logical ISLs (LISLs) in user-defined logical switches.
Frame monitor: Any frame monitors on the port are deleted. To keep the frame monitor, the
monitor must be manually installed on the port after the move.
Top Talker (fabric mode): If the fabric-mode Top Talkers feature is enabled on the logical switch,
a fabric mode Top Talker monitor is automatically installed on the port after it is moved to the
logical switch.
Top Talker (port mode): Any port mode Top Talker monitors on the port are deleted. To keep the
port mode Top Talker monitor, the monitor must be manually installed on the port after the
move.
lists the platforms that support logical switches and, for each
8
4
4
3
4
Maximum number of logical switches on which
monitors are supported
4
4
4
3
3
Fabric OS Administrator's Guide
53-1002745-02

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fabric os 7.1.0

Table of Contents