HP StoreFabric SN6500B Administrator's Manual page 409

Fabric os administrator's guide, 7.1.0 (53-1002745-02, march 2013)
Hide thumbs Also See for StoreFabric SN6500B:
Table of Contents

Advertisement

Rate Limit
EX Port
Mirror Port
Credit Recovery
F_Port Buffers
Fault Delay:
NPIV PP Limit:
CSCTL mode:
Frame Shooter Port
D-Port mode:
Compression:
Encryption:
FEC:
myswitch:admin>
Enabling compression
Finally, you enable compression on the same port. The subsequent portCfgShow command shows
both encryption and compression to be enabled on the port.
myswitch:admin> portdisable 0
myswitch:admin> portcfgcompress --enable 0
Turning ON Compression on port(0) will cause the port to be disabled during next
LOGIN
myswitch:admin> portenable 0
myswitch:admin> portcfgshow 0
Area Number:
Octet Speed Combo:
Speed Level:
AL_PA Offset 13:
Trunk Port
Long Distance
VC Link Init
Locked L_Port
Locked G_Port
Disabled E_Port
Locked E_Port
ISL R_RDY Mode
RSCN Suppressed
Persistent Disable
LOS TOV enable
NPIV capability
QOS E_Port
Port Auto Disable:
Rate Limit
EX Port
Mirror Port
Credit Recovery
F_Port Buffers
Fault Delay:
NPIV PP Limit:
CSCTL mode:
Frame Shooter Port
D-Port mode:
Compression:
Encryption:
FEC:
myswitch:admin>
Fabric OS Administrator's Guide
53-1002745-02
Encryption and compression examples
OFF
OFF
OFF
ON
OFF
0(R_A_TOV)
126
OFF
OFF
OFF
OFF
ON
OFF
0
3(16G,10G)
AUTO(SW)
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
AE
OFF
OFF
OFF
OFF
ON
OFF
0(R_A_TOV)
126
OFF
OFF
OFF
ON
ON
OFF
14
409

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fabric os 7.1.0

Table of Contents