Disabling bottleneck detection on a switch

Disabling bottleneck detection on a switch

When you disable bottleneck detection on a switch, all bottleneck configuration details are
discarded, including the list of excluded ports and non-default values of alerting parameters.
Use the following procedure to disable bottleneck detection:
1. Connect to the switch and log in using an account with admin permissions.
2. Enter the bottleneckmon --disable command to disable bottleneck detection on the switch.
Example of disabling bottleneck detection on a switch
392
switch:admin> bottleneckmon --disable
switch:admin> bottleneckmon --disable
switch:admin> bottleneckmon --status
Bottleneck detection - Disabled