SAN management with Admin Domains
LSAN zone names in AD0 are never converted for backward-compatibility reasons.
The auto-converted LSAN zone names might collide with LSAN zone names in AD0 (in the example,
if AD0 contains lsan_for_linux_farm_AD005, this causes a name collision). Fabric OS does not
detect or report such name clashes.
LSAN zone names greater than 57 characters are not converted or sent to the FCR phantom
domain.
LSAN zones defined within an Admin Domain must contain devices that are applicable to that
Admin Domain only. A device must not be included in more than one LSAN zone across multiple
Admin Domains. Device discovery problems might occur if LSAN zones in one Admin Domain
contain devices that belong to another Admin Domain.
Refer to

Configuration upload and download in an AD context

The behavior of the configUpload and configDownload commands varies depending on the AD
context and whether the switch is a member of the current Admin Domain. In the AD context, these
commands include only the zone configuration of the current Admin Domain. If the switch is a
member of the Admin Domain, all switch configuration parameters are saved and the zone
database for that Admin Domain is also saved.
Table 68
can upload and download these sections. Refer to
Configuration File,"
NOTE
You cannot use configDownload to restore a single Admin Domain. To restore a single Admin
Domain, you must first delete all Admin Domains and then issue configDownload to restore them.
TABLE 68
AD contexts
AD255:
AD0:
AD1 – AD254: With switch membership
1.
2.
3.
The configDefault command does not clear zone or Admin Domain database information.
This command is allowed only if the switch is a member of the current Admin Domain.
460
Chapter 24, "Using FC-FC Routing to Connect Fabrics,"
lists the sections in the configuration file and the Admin Domain contexts in which you
for additional information about uploading and downloading configurations.
Configuration upload and download scenarios in an AD context
With ADs
Without ADs
With ADs and switch membership
With ADs and without switch membership
Without ADs
Without switch membership
Zone databases for AD0 through AD254.
Only zone database for AD0.
Only zone database for current AD.
for information about LSAN zones.
Chapter 8, "Maintaining the Switch
Configuration file sections
iSCSI
ACL
Zone
AD headers
1
Yes
Yes
Yes
Yes
1
Yes
Yes
Yes
Yes
2
Yes
No
Yes
No
2
Yes
No
Yes
No
2
Yes
Yes
Yes
No
3
No
No
Yes
No
3
No
No
Yes
No
Fabric OS Administrator's Guide
Switch configuration
and other parameters
Yes
Yes
Yes
No
Yes
Yes
No
53-1002745-02

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fabric os 7.1.0

Table of Contents