Configuring Backbone Fabrics For Interconnectivity - HP StoreFabric SN6500B Administrator's Manual

Fabric os administrator's guide, 7.1.0 (53-1002745-02, march 2013)
Hide thumbs Also See for StoreFabric SN6500B:
Table of Contents

Advertisement

11. Log in as an admin and connect to the FC router.
12. Enter the following commands to display information about the LSANs:
On the FC router, the host and Target A are imported, because both are defined by
lsan_zone_fabric2 and lsan_zone_fabric75. However, Target B is defined by lsan_zone_fabric2
and is not imported because lsan_zone_fabric75 does not allow it.
When a PLOGI, PDISC, or ADISC arrives at the FC router, the SID and DID of the frame are checked.
If they are LSAN-zoned at both SID and DID edge fabrics, the frame is forwarded to the DID. If they
are not zoned, only the PLOGI is dropped; for the remaining frames zoning enforcement takes place
in the edge fabrics.

Configuring backbone fabrics for interconnectivity

If you want devices in backbone fabrics to communicate with devices in edge fabrics, set up the
LSANs as described in the section
However, instead of configuring the LSAN in the second edge fabric, configure the LSAN in the
backbone fabric.
Fabric OS Administrator's Guide
53-1002745-02
This action will replace the old zoning configuration with the
current configuration selected.
Do you want to enable 'zone_cfg' configuration
zone config "zone_cfg" is in effect
Updating flash ...
lsanZoneShow -s shows the LSAN.
switch:admin> lsanzoneshow -s
Fabric ID: 2 Zone Name: lsan_zone_fabric2
10:00:00:00:c9:2b:c9:0c
50:05:07:61:00:5b:62:ed
50:05:07:61:00:49:20:b4
Fabric ID: 75 Zone Name: lsan_zone_fabric75
10:00:00:00:c9:2b:c9:0c
50:05:07:61:00:5b:62:ed
fcrPhyDevShow shows the physical devices in the LSAN.
switch:admin> fcrphydevshow
Device
Exists
in Fabric
-----------------------------------------
75 10:00:00:00:c9:2b:c9:0c c70000
2
50:05:07:61:00:49:20:b4 0100ef
2
50:05:07:61:00:5b:62:ed 0100e8
Total devices displayed: 3
fcrProxyDevShow shows the proxy devices in the LSAN.
switch:admin> fcrproxydevshow
Proxy
WWN
Created
in Fabric
----------------------------------------------------------------------------
75
50:05:07:61:00:5b:62:ed
2
10:00:00:00:c9:2b:c9:0c
Total devices displayed: 2
Imported
EXIST
EXIST
EXIST
Imported
WWN
Physical
Proxy
Device
PID
Exists
in Fabric
01f001
02f000
"Controlling device communication with the LSAN"
LSAN zone configuration
(yes, y, no, n): [no] y
PID
Physical
PID
2
0100e8
Imported
75
c70000
Imported
24
State
on page 591.
593