11. Remove the BIOS recovery diskette from the diskette drive.
12. Turn off the server, and disconnect all power cords and external cables; then,
13. Move the BIOS recovery jumper back to pins 1 and 2 to return to normal
14. Reconnect all external cables and power cords, and turn on the peripheral
15. Restart the server.

System event/error log messages

A system event/error log is generated only if a Remote Supervisor Adapter II
SlimLine is installed. The system-error log can contain three types of messages:
Information
Warning
Error
Each message contains date and time information, and it indicates the source of
the message (POST/BIOS or the service processor).
Note: The BMC system event log, which you can view through the
Configuration/Setup Utility program, also contains several information, warning, and
error messages.
In the following example, the system event/error log message indicates that the
server was turned on at the recorded time.
The following table describes the possible system-error log messages and
suggested actions to correct the detected problems.
remove the server cover.
startup mode.
devices; then, reinstall the server cover.
Information messages do not require action; they record significant
system-level events, such as when the server is started.
Warning messages do not require immediate action; they indicate
possible problems, such as when the recommended maximum
ambient temperature is exceeded.
Error messages might require action; they indicate system errors,
such as when a fan is not detected.
- - - - - - - - - - - - - - - - - - - - -
Date/Time: 2002/05/07 15:52:03
DMI Type:
Source: SERVPROC
Error Code: System Complex Powered Up
Error Code:
Error Data:
Error Data:
- - - - - - - - - - - - - - - - - - - - -
157