IBM x3655 - System - 7985 Service Manual page 189

Problem determination and service guide
Hide thumbs Also See for x3655 - System - 7985:
Table of Contents

Advertisement

v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 4, "Parts listing, System x3655, Type 7985," on page 97 to determine which components are
customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
BMC log message
Remote Supervisor
Adapter II SlimLine detect
ABR status
CPU 1 status
Assertion 01 (Thermal
trip)
CPU 1 status
Assertion 05
(Configuration error)
CPU 1 status
Assertion 07 (Processor
presence detected) or 0A
(Processor automatically
throttled)
CPU 1 status
Assertion 08 (Processor
disabled)
CPU 2 status
Assertion 01 (Thermal
trip)
CPU 2 status
Assertion 05
(Configuration error)
CPU 2 status
Assertion 07 (Processor
presence detected) or 0A
(Processor automatically
throttled)
CPU 2 status
Assertion 08 (Processor
disabled)
Sensor
Sensor
number
type
Action
8C
17
1. Make sure that the Remote Supervisor Adapter II SlimLine is
2. Replace the Remote Supervisor Adapter II SlimLine.
8F
0F
Information only
90
07
Information only; if the message remains:
1. Make sure that the fans have good airflow and are not
2. (Trained service technician only) Reseat the microprocessor.
3. (Trained service technician only) Replace the microprocessor.
90
07
(Trained service technician only) Make sure that the
microprocessor is installed correctly.
90
07
Information only
90
07
1. Check the DIMM error LEDs on the system board.
2. (Trained service technician only) Reseat the microprocessor.
3. (Trained service technician only) Reseat the microprocessor.
4. (Trained service technician only) Replace the microprocessor.
91
07
Information only; if the message remains:
1. Make sure that the fans have good airflow and are not
2. (Trained service technician only) Reseat the microprocessor.
3. (Trained service technician only) Replace the microprocessor.
91
07
(Trained service technician only) Make sure that the
microprocessor is installed correctly.
91
07
Information only
91
07
1. Check the DIMM error LEDs on the microprocessor.
2. (Trained service technician only) Reseat the microprocessor.
3. (Trained service technician only) Replace the microprocessor.
fully seated in the connector.
obstructed.
obstructed.
171
Chapter 5. Diagnostics