Ipmi Bmc System-Error Log Messages - IBM x3655 - System - 7985 Service Manual

Problem determination and service guide
Hide thumbs Also See for x3655 - System - 7985:
Table of Contents

Advertisement

v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 4, "Parts listing, System x3655, Type 7985," on page 97 to determine which components are
customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
System event/error log message
Processor VTT power fault

IPMI BMC system-error log messages

The following table describes the possible IPMI BMC system-event log messages
and suggested actions to correct the detected problems.
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 4, "Parts listing, System x3655, Type 7985," on page 97 to determine which components are
customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
BMC log message
System event
Assertion 00 (System
reconfigured)
Battery
Assertion 01 (Battery
failed)
System firmware
progress
Assertion 0002 (No
usable system memory)
System firmware
progress
Assertion 000B (Firmware
ROM corrupted)
System firmware
progress
Assertion 010B (SMBUS
error)
Memory error
Assertion 35xx
(Correctable ECC
memory error logging
limit reached DIMM xx
164
IBM System x3655 Type 7985: Problem Determination and Service Guide
Action
1. (Trained service technician only) Reseat microprocessor 1.
2. (Trained service technician only) Replace microprocessor 1.
3. (Trained service technician only) Replace the system board.
Sensor
Sensor
number
type
Action
00
12
Information only
00
29
Replace the battery.
00
0F
1. Reseat the DIMMs.
2. Replace the DIMMs.
3. Replace the microprocessor.
4. (Trained service technician only) Replace the system board.
00
0F
1. Use the Boot recovery (BIOS) jumper (J35) to switch to the
2. (Trained service technician only) Replace the system board.
00
0F
(Trained service technician only) Replace the system board.
00
0C
Information only
secondary BIOS page.