Bios-Logged Bmc System-Error Log Messages - IBM x3655 - System - 7985 Service Manual

Problem determination and service guide
Hide thumbs Also See for x3655 - System - 7985:
Table of Contents

Advertisement

v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 4, "Parts listing, System x3655, Type 7985," on page 97 to determine which components are
customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
BMC log message
Processor n initiated sync
flood: Slot n error
(possible timeout
condition)
Secondary HT2100
initiated sync flood: PCI-e
slot n error
PCI PME
DASD backplane detect
IDE cable detect
SEL fullness
CPU 1 hot
CPU 2 hot
CPU 3 hot
CPU 4 hot

BIOS-logged BMC system-error log messages

BIOS can log two types of system-event log messages: POST events, which occur
during system start-up, and SMI events, which are generally run time errors
detected by hardware.
The server logs OEM-specific BIOS messages in the BMC system-event log. The
following table describes the four BIOS sensor types logged in the BMC
system-event log. You can obtain third-party software to provide BMC system-event
log translations for detailed byte definitions and repair actions.
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v SeeChapter 4, "Parts listing, System x3655, Type 7985," on page 97 to determine which components are
customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
Sensor type
OEM POST with time stamp
Sensor
Sensor
number
type
Action
AB-AC
21
1. Reseat the failing adapter.
2. Replace the failing adapter.
3. (Trained service technician only) Replace the system board.
AB-AC
21
1. Reseat the failing adapter.
2. Replace the failing adapter.
3. (Trained service technician only) Replace the system board.
AC
09
Information only
AD
1B
Information only
AE
1B
Information only
B6
D0
Information only
C0
01
Information only
C1
01
Information only
C2
01
Information only
C3
01
Information only
Sensor type code
0xC0
Byte definition and description
Byte 11 POST Error/Event Type
0x00 POST PCI POST Event/Error
0x01 POST PCI Processor Event/Error
0x02 POST Memory Event/Error
0x04 POST Bus Event/Error
0x05 POST Chipset Event/Error
Chapter 5. Diagnostics
173