Intermittent Problems - IBM x3655 - System - 7985 Service Manual

Problem determination and service guide
Hide thumbs Also See for x3655 - System - 7985:
Table of Contents

Advertisement

Intermittent problems

v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 4, "Parts listing, System x3655, Type 7985," on page 97 to determine which components are
customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
Symptom
A problem occurs only
occasionally and is difficult to
diagnose.
The server resets (restarts)
occasionally
128
IBM System x3655 Type 7985: Problem Determination and Service Guide
Action
1. Make sure that:
v All cables and cords are connected securely to the rear of the server and
attached devices.
v When the server is turned on, air is flowing from the fan grille. If there is no
airflow, the fan is not working. This can cause the server to overheat and
shut down.
2. Check the system event/error log or BMC system event log (see "Error logs" on
page 116).
3. See "Solving undetermined problems" on page 177.
1. If the reset occurs during POST and the POST watchdog timer is enabled (click
Advanced Setup --> Baseboard Management Controller (BMC) Settings -->
BMC Post Watchdog in the Configuration/Setup Utility program to see the
POST watchdog setting), make sure that sufficient time is allowed in the
watchdog timeout value (BMC POST Watchdog Timeout). See the User's
Guide for information about the settings in the Configuration/Setup Utility
program.
If the server continues to reset during POST, see "POST" on page 107 and
"Diagnostic programs, messages, and error codes" on page 144.
2. If the reset occurs after the operating system starts, disable any automatic
server restart (ASR) utilities, such as the IBM Automatic Server Restart IPMI
Application for Windows, or ASR devices that may be installed.
Note: ASR utilities operate as operating-system utilities and are related to the
IPMI device driver.
If the reset continues to occur after the operating system starts, the operating
system might have a problem; see "Software problems" on page 137.
3. If neither condition applies, check the system event/error log or BMC system
event log (see "Error logs" on page 116).
If the problem remains, call for service.

Advertisement

Table of Contents
loading

This manual is also suitable for:

System x3655 type 7985

Table of Contents