Status - Cisco WS-C3550-12G User Manual

User guide
Hide thumbs Also See for WS-C3550-12G:
Table of Contents

Advertisement

Chassis Management Window

Status

The Status area provides the following information:
Note
Note
Cisco Catalyst Switch Manager User Guide
6-4
Firmware version
Software version
Core Temperature Status—Status of the core of the chassis. This attribute can have the following
values:
Excessive—The current temperature is within normal operating parameters.
Normal—The current temperature has exceeded the normal operating range.
High—The current temperature is dangerously high. The system will shutdown imminently.
If this attribute has a value other than off, an alarm is generated.
Fan Status—Status of the chassis fans. This attribute can have the following values:
other—The fan status is unknown.
Normal—Fan status is normal.
High—There is a minor problem.
Excessive—There is a major problem.
If this attribute has a value other than ok, an alarm is generated.
Clock 1 Status, Clock 2 Status—Operational statuses of clocks 1 and 2. These attributes can have
the following values:
OK—Clock is operating.
failed—Clock is not operating.
Clock 1 In Use, Clock 2 In Use—Indicates which clock is in use. These attributes can have the
following values:
in-use—Clock is in use.
not-in-use—Clock is not in use.
VTT 1 Status, VTT 2 Status, VTT 3 Status—Operational status of VTT 1, VTT 2, and VTT 3. These
attributes can have the following values:
OK—VTT is operating.
failed—VTT is not operating.
VTT 1 Outlet Temperature, VTT 2 Outlet Temperature, VTT 3 Outlet Temperature—Outlet
Temperatures of VTT 1, VTT 2, and VTT 3. These attributes can have the following values:
<n>C—Temperature in degrees Celsius.
N/O—Indicates that the sensor is not operational.
N/A—Indicates that the sensor value is not available.