Cisco IE-3000-8TC Administration Manual page 327

Administration guide
Hide thumbs Also See for IE-3000-8TC:
Table of Contents

Advertisement

Setting
Ka
Kd
Metering
NC Congestion
Request Category
Click Finish to complete adding a PSTN connection to Cisco Business Edition 3000 server. You can add up
to 300 connections.
OL-27022-01
Description
This is the category of the calling party sent in
response to Backward Group-A-6 signal. For
incoming calls, the Ka value is collected. For outgoing
calls, the Ka value is sent if configured. Otherwise,
the default category for the country is sent.
The default value is 1 (applicable only for China).
This is the category sent in response to Backward
Group-A-3 signal. For incoming calls, the Kd value
is collected. For outgoing calls, the kd value is sent
if configured. Otherwise, the default category for the
country is sent.
The default value is 1 (applicable only for China).
Metering signals are pulse type signals transmitted
backward during the call from call charging point to
the subscriber call meter in the originating exchange.
This pulse can be "pulsed clear-back" (01 to 11 and
back) or "pulsed answer" (11 to 01 and back). To
avoid confusion with metering signals, clear-back
signal is not allowed. If metering is on, Forced
Release (00) is sent instead of Clear-Back (11).
The default value is False
Specify the Backward Group-B congestion signal for
non-compelled signaling. If this is not configured,
the gateway uses the default Backward Group-B-4
signal.
The default value is 4.
Specify the DNIS digits to be collected before
requesting category.