3
Lines/Trunks
Selecting Line/Trunk Options
b.
Table 3-4.
Setting
1 (factory setting)
2
3
4
5
1 Based on 22-gauge cable.
8.
If the system includes both 800 NI-BRI and 100D modules, clock
synchronization planning should be completed at the same time. There is
only one primary/secondary/tertiary clock for both 800 NI-BRI modules and
100D modules, with the same system programming screens used for both
types.
If the switch is part of a private network, clock synchronization needs to be
coordinated for the entire network. See the Network Reference for
information.
Plan your clock source administration to minimize the need for clock
switching, which is known to cause noise on active calls.
Under Priority in the Clock Synchronization section, do either of the
following:
Use
Table 3-4
to select the line compensation setting needed. (The
factory setting is 1.)

Line Compensation Settings

dB Loss
-0.6
-1.2
-1.8
-2.4
-3.0
If installing only one 100D module:
— To keep the factory setting, check Primary (that is, this
module provides synchronization for the system).
— If the synchronization source is other than through the 100D
module, check None.
If installing more than one 100D module, decide which module, if
any, provides the primary synchronization:
— If Module 1 provides clock synchronization, check Primary in
the first box (the factory setting).
— If Module 2 (or Module 3) provides clock synchronization,
check Primary in the box that describes that 100D module.
— If the synchronization source is other than through a 100D
module, check None.
1
Cable Feet
0 133
133 266
266 399
399 533
533 655
Issue 1
April 1999
3-33