Unit Load Calculation
Unit Load Worksheet
6. Calculate the actual carrier unit load using the following table.
If the total actual unit load is less than or equal to 96 (391C1 power supply),
72 (for the 391A3 power supply), or less than or equal to 48 (391A1 or
391A2 power supplies), no further calculation is required.
If the total actual unit load is more than 96 (391C1 power supply), 72 (for
the 391A3 power supply), or 48 (391A1 or 391A2 power supplies),
continue to Step 7.
Equipment
Network Access Lines
DID
DS1
NI-1 BRI
GS/LS
Tie
Telephones
MLX-5
MLX-5D
MLX-10
MLX-10D
MLX-10DP
MLX-16DP
MLX-28D
MLX-20L
ETR-6
ETR-18
ETR-18D
ETR-34D
MLS-6
MLS-12
Qty x
Unit Load
Hybrid/PBX
or Modified
1
Key
1.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
1.4
1.4
0.9
1.2
0.9
1.2
0.9
1.2
0.9
1.2
0.9
1.2
1.5
1.5
1.2
1.7
1.1
1.6
0.8
0.8
0.9
0.9
1.0
1.0
1.0
1.0
0.7
0.7
0.8
0.8
Issue 1
April 1999
F-5
= Total