MERLIN LEGEND Communications System Release 7.0
System Planning 555-670-112
Prior Releases: Features and Enhancements
Release 2.1 Enhancements (August 1994)
When an MLX telephone, other than an MLX-20L, is plugged into an MLX
port and the Personal Directory does not contain any entries, the allocation
of the Personal Directory resource is released. If there are any entries in
the Personal Directory, the Personal Directory allocation and the entries in
the Personal Directory are saved in the MLX port.
SMDR call records for calls made on PRI facilities are more accurate than
SMDR call records for calls made on non-PRI facilities. Outgoing calls
made on PRI facilities receive "answer supervision." Consequently, SMDR
timing for calls made on PRI facilities begins when the call is answered.
Timing for calls made on non-PRI facilities begins when dialing is
completed. Therefore, an SMDR call record is not generated when a call
made on a PRI facility is not answered at the far end.
The Call Type field and the Called Number field on the SMDR report are
changed for both the Basic and ISDN report formats.
An 012 port that is programmed as a generic voice messaging interface
(VMI) port can transfer an outside call to an outside number.
In a system where the transfer audible option is programmed for
Music-On-Hold and a music source is provided, outside callers who are
transferred to a calling group and are waiting in the queue or who are
parked or camped-on, hear music while they are waiting. Internal callers
never hear music on hold while waiting in the calling group queue or when
they are parked, camped-on, or being transferred to another extension.
Installation and Hardware
Installation and hardware enhancements include the following:
The control unit covers for the MERLIN LEGEND Communications System
are the same easy-to-use covers as those for the MERLIN II
Communications System.
A new 012 (tip/ring) module [apparatus code 517G13 (28) or higher letter]
contains a built-in ring generator. The maximum ring equivalency number
(REN) supported is 2.2, and the module will ring four ports at one time.
Bridging of single-line telephones is not supported because of poor
transmission quality.
A new 008 OPT module (labeled "with RING GEN.") contains a built-in ring
generator. It rings four ports at a time.
Ferrite cores for the power supply modules are shipped from the factory to
comply with FCC Part 15 requirements.
3129-WTWA (touch tone outdoor telephone equipped with cast aluminum
housing and armored handset cord with bell ringers)
3129-WRWA (rotary dial outdoor telephone equipped with cast aluminum
housing and armored handset cord with bell ringers).