Ensured that the new member switch has the factory-default configuration. If the new
member switch has been previously configured, revert its configuration to the factory
defaults. For information about reverting to the factory default configuration, see the
Dell PowerConnect J-Series Ethernet Switch Complete Software Guide for Junos OS at
http://www.support.dell.com/manuals
Made a note of the serial number (on the back of the switch). You will need to edit the
Virtual Chassis configuration to include the serial number of the new member switch.
Edited the existing Virtual Chassis preprovisioned configuration to include the serial
number of the new member switch. You can specify the role of the new member switch
when you add its serial number to the Virtual Chassis configuration file. The parameters
specified in the master Virtual Chassis configuration file are applied to the new member
switch after it has been interconnected through its uplink VCP to an existing member
switch.
Prepared an existing member switch to interconnect with the new switch through an
uplink module port by configuring an uplink module port as a VCP on the existing
member switch.
Ensured that the operational modes of the uplink modules on the existing member
switch and the new member switch match.
Confirmed that the new member switch is powered off.
Interconnected the existing switch with the new switch using the appropriate cable.
If these conditions are not met, autoprovisioning will not work and you will need to
manually configure uplink module ports on the switch to be added to the configuration
to be VCPs. For information about setting an uplink module as a Virtual Chassis port, see
the Dell PowerConnect J-Series Ethernet Switch Complete Software Guide for Junos OS
at
http://www.support.dell.com/manuals
To add a switch to an existing preprovisioned Virtual Chassis configuration using the
autoprovisioning feature:
Power on the new member switch.
1.
Confirm that the new member switch is now included in the Virtual Chassis
2.
configuration by checking the front-panel display for the member ID. It should display
a member ID in the range from 0 through 9 because there was already at least one
member of the Virtual Chassis configuration. The member ID is automatically assigned
to the new member switch's serial number in the configuration file.
Related
Replacing a Member Switch of a Virtual Chassis Configuration (CLI Procedure) on
Documentation
page 148
For more information about Virtual Chassis configuration, see the Dell PowerConnect
J-Series Ethernet Switch Complete Software Guide for Junos OS at
http://www.support.dell.com/manuals