Setting General Trunk Attributes
Parameter
Protocol
Dialing Delay
Caller ID and DID Collection
You can select the maximum time-out delays, in seconds and the appropriate
sequence of symbols to be collected for Caller ID and DID.
Max. seconds
before the first
digit
Max. seconds
between digits
7-18 AltiContact Manager Administration Manual
Description
You can set Protocol to one of the following:
• E&M Wink Start (default)
• E&M Immediate Start
• Ground Start
• Loop Start
For signaling from one board to another, only FXS
(Foreign Exchange Subscriber) is supported. Loop Start
and Ground Start protocols cannot be used for interfacing
between two boards.
Specifies the delay, in milliseconds, after trunk seizure and
before digit dialing. Do not change this value unless
advised.
Maximum wait time before time-out for the system to
identify this digit after either the first ring in ground start or
loop start or the wink in wink start. The range is from 1-6
seconds, or None, with a default value of 3 seconds. Do not
change this value unless advised.
'None' means no Caller ID or DID information will be
collected. All other options will be grayed out. Use this
option to disable Caller ID and DID collection.
Maximum wait time before time-out between two digits.
Default value is 'None.' Do not change this value unless
advised.
Selecting 'None' means the system will only wait for the
sequence of digits that are collected within the length of
time specified in the Max. seconds before the first digit
field.