C
H
A
P
T
E
460T Ch1.p65
R
1
Express 460T Switch Features and Setup
Selecting the right cable
Media Type
100Base-FX Module
(full duplex)
100Base-FX Module
(half-duplex)
1000Base-T\100Base-TX
(Gigabit) Module
1000Base-SX
(Gigabit) Module
1000Base-LX
(Gigabit) Module
Testing a cable
When using a 100Base-TX module, you can quickly check the cable's link
integrity by plugging one end into port 1 and the other end into port 2. Make
sure the MDI/MDI-X button is out. Check the Activity LEDs for ports 1 and
2. If the LEDs are on, you have a functioning crossover cable.
If the LEDs are off, push the MDI/MDI-X button in. If the Activity LEDs
for ports 1 and 2 turn on, you have a functioning straight-through cable.
However, if the LEDs remain off, you probably have a bad cable.
If a cable passes these tests, but the network connection is slow, verify that
wires 1, 2 and 3, 6 on the cable are twisted pairs as shown in the diagrams
on the next page.
9
Cabling Used
62.5/125 m multimode
62.5/125 m multimode
Category 5 (CAT 5) unshielded
twisted pair cable
50/125 m multimode
62.5/125 m multimode
50/125 m multimode
62.5/125 m multimode
9/125 m singlemode
4/19/00, 11:01 AM
Maximum distance
2,000m
(160m to a hub, 400m to
a router, switch, or PC)
100m
550m
260m
550m
550m
5,000m
9
Need help?