HP LC2000r - NetServer - 128 MB RAM Installation Manual page 136

Hp netserver lh 6000 installation guide
Hide thumbs Also See for LC2000r - NetServer - 128 MB RAM:
Table of Contents

Advertisement

Chapter 10
NOTE
If SCSI A and B on the I/O board are operating in RAID mode,
the prompt to press CTRL+C is not displayed. To change to
non-RAID mode, refer to "Start Setup Utility."
If you wait too long to press the Ctrl+C keys, you may not be
able to enter the Symbios Configuration utility, even though
the message "Press Ctrl-C to start Symbios Configuration
Utility..." is still displayed. If this happens, restart the
HP NetServer, and press the Ctrl+C keys as soon as the
message appears.
3. When the Symbios Logic SCSI Configuration Utility Main Menu is
displayed, verify that shows Display=Verbose. (This means that the non-
RAID SCSI devices will be listed on the boot screen.)
If not, use the up and down arrow keys to highlight Display=Terse. Press
Enter to change the setting to Verbose.
4. On the Symbios Logic SCSI Configuration Utility Main Menu, verify that
the Current Status of all Symbios controllers (adapters) is On.
If not, use the up and down arrow keys to highlight Change Adapter
Status. Press Enter to display the Change Status on Next Boot window.
Use the up and down arrow keys to highlight the controller, and press
Enter to change its Next-Boot Status to On. Press Esc to return to the
Main Menu.
5. On the Symbios Logic SCSI Configuration Utility Main Menu, use the up
and down arrow keys to highlight Adapter Boot Order. Press Enter to
select it.
128
Configuring the HP NetServer