Installing the HP NetServer in an HP Rack System/E or Rack System/U

HP NetServer Rack Mount Parts List

Make sure that the rack-mount kit that accompanies the HP NetServer contains the
following parts:
Table 8-1. Parts for Rack Mount Kit
Quantity
2
8
8
6
1

Rack-Mounting the HP NetServer

Install the slides, which hold the HP NetServer in the rack. Do this by first
marking a baseline based on where you want the HP NetServer in the rack.

Marking your Front Column Baseline and Slide Mounting Holes

To determine the hole position for rack nuts and bar nuts, which will secure the
slides to the rack, mark the slide mounting holes on all columns.
1. Mark the bottom of the HP NetServer at an EIA unit mark on the column.
This is your baseline.
NOTE
The EIA unit marks are stamped in the sheet metal of the
columns. Use the rack template to mark the correct holes for
mounting (on all four columns).
2. Hold the bottom of the rack template at the baseline.
3. Mark the top of HP NetServer (eight EIA units up from the baseline).
4. Mark the slide screw mounting holes (holes 20 and 22 up from the
baseline).
5. Mark the remaining columns by repeating steps 1 through 4.
Description
Slides
Rack Nuts
Rack Nut Screws (M5 x 16mm)
Screws for Slides (8-32 x ¼ inch)
Template