Table of Contents HP NetServer LC System Views Front Bezel and Cover System Board System Board Connectors, Switches, and Jumpers System Board Connector J7 SW1 Switch and Default Settings Processor Boards Intel 486 Processor Board with Optional 256 KB Cache Pentium™...
Page 4
Memory Processor Board LED Blink Codes Boot Device Priority Cabling Configurations Configuring Switch Settings on the Hot Swap Subsystem Hot Swap Subsystem SCSI Address Settings Exploded Views Parts List Mass Storage Cables Keyboards Power Cords Specifications HP NetServer LE System Views Installation View Exploded View HP NetServer LE Parts List...
Page 5
HP NetServer LH Plus Parts List HP NetServer LH Plus Mass Storage Cables HP NetServer LH Pro Exploded Views HP NetServer LH Pro Replaceable Parts List HP NetServer LH Pro Mass Storage Cables HP NetServer LH Keyboards HP NetServer LH Power Cords HP NetServer LH System Board and Connectors HP NetServer LH System Board Connectors, Switches, and Jumpers HP NetServer LH Plus/Pro System Board and Connectors...
Page 6
Hot-Swap Hard Disk Drive LED Status and Activity Indicators System Board System Switches Cabling Cables and Part Numbers Specifications HP NetServer LM System Views Exploded View Parts List HP NetServer LM Keyboards HP NetServer LM Power Cords System Board System Board Jumper Locations System Board Jumper Settings Memory Video Memory - DRAM...
Page 7
Control Panel Connector J1 Mass Storage Indicator Lights Cover Exploded Views Parts List Keyboards Power Cords Mass Storage Cables System Board System Board Connectors System Switches and Jumpers Memory Configuration Video Memory - DRAM Boot Device Priority Cabling Configuring Switch Settings on the Hot Swap Subsystem Hot Swap Subsystem SCSI Address Settings Specifications Notes...
HP NetServer LC System Views Control Panel Line Voltage Selection Switch Power Cable Clamp Keyboard Mouse Serial Port B Serial Port A Video Parallel Port SCSI External Port PCI Slot 6 PCI or EISA/ISA Slot 5 EISA/ISA Slot 1...
Front Bezel and Cover Bezel handles System Board Keyboard Mouse Serial port B IO Panel Serial port A Connectors Parallel port LPT1 Side view Monitor External SCSI port...
Control panel cable connector Power P1 & P2 Battery connector Power Adapter Power Supply On (HP Remote Assistant) Flexible disk drive cable connector IDE disk drive cable connector Internal SCSI connector Pin 1 Power P3 & P4 Mounting pin Main fan connector SW1 system board switches Slot 3 - PCI...
System Board Connector J7 This connector is used by the HP Remote Assistant Accessory -- a 32-bit EISA Bus Master board used to remotely monitor server functionality. For additional information on this product, see the documentation that comes with it. When you install the HP Remote Assistant cable, you will need to remove the jumper on PS REMOTE and PS ON.
PASSWORD ENABLE: Enables or erases the power-on password maintained in NVRAM. ON: Power-on password functional. OFF: Erases the current power-on password. SMI# ENABLE: Not used - leave in default position OFF: Prevents SMI interrupt. IO CTRL ENABLE: Enables or disables onboard flexible disk drive controller, IDE controller, and serial and parallel ports.
Jumper Setting (Not on 66 Board) /100, /133 /75 75/100 Bank 0/1 Bank 2/3 Bank 4/5 5/100, 5/133, 5/166 Pentium™ Processor Board Before installing this board, verify that jumper setting J1 is set to VRE and jumper setting J2 is set to the correct speed for your chip as shown in the illustration below.
You must install SIMMs in pairs (called banks) of matching size; however, the banks can be of different sizes. To achieve large memory configurations (greater than 144 MB) with the Pentium processor, you must remove and replace the SIMMs that are already installed in the server. If you obtain SIMMs from other sources, for 16 MB and 32 MB SIMMs, the speed must be 60 or 70 ns.
Exploded View Parts List Description Replacement Exchange Front bezel 5063-5617 535 MB SCSI HDD D2075-60003 D2075-69001 540 MB SCSI HDD D2386-63001 D2386-69001 1 GB SCSI HDD D2076-63102 D2076-69002 2.1 GB HDD D2077-63100 D2077-69001 1.44 MB 3.5" Flexible disk drive D2035-63004 Mass storage cage 5063-0397...
Page 17
Description Replacement Exchange Chassis with door, fan, mass storage cage 5064-0744 Control Panel PCA 5063-5607 Battery (4.5 volt alkaline) 1420-0502 Power supply (200w) 5063-5689 3160-0860 System Board -- no ROM D3310-63006 D3310-69006 System ROM 486 D3310-80201 System ROM P/66 D3314-80201 System ROM P5/75, 100, 133 ROM D3594-80205 CPU Board Pentium 486/66 board -- no processor,...
Description Replacement Exchange DeskDirect NIC J2973-61001 HP Navigator CD-ROM D3600A ** NS Server Saver Test Disk 5010-8878 Diagnostic Assistant Diskette 5063-8343 ** * This part is not on an exploded view. * * This part number is constantly revised. When you order the CD-ROM, you will be sent the latest revision. Keyboards Language HP Part Number...
Specifications Power Supply 100 to 127 VAC ~ 6.0 A or 200 to 240 Volts AC ~ 3.14 A at 50 to 60 Hertz Power Availability 224 watts peak, 200 watts continuous Power Consumption 301/351 watts peak with 110-volt line maximum voltage 291/337 watts peak with 220-volt line maximum voltage System Dimensions 16.7 in.
HP NetServer LC 3 System Views Power Switch Keyboard Lock Serial Port B Serial Port A Parallel Port Mouse Port Keyboard Port Lock Monitor Flexible Management Port Disk Drive EIDE CD-ROM Shelf 3 Power Hot Swap Drive Bay Hot Swap Drive Bay Lock Front Control Panel Power Switch Turns the NetServer on and off.
Covers CAUTION The covers are an integral part of the server. The server must be operated with the covers in place to ensure proper airflow for continued reliability and to maintain compliance with radio frequency interference and safety standards. Front Bezel Cover Pocket...
Memory There are four DIMM sockets on the system board for memory expansion Follow these simple rules when you plan to install additional memory DIMMs: Use only HP DIMMs listed on the Technical Reference Label located inside the HP NetServer top cover, in Information Assistant, or in Order Assistant.
Video Memory Expand video memory by installing two 256 K x 16 (512 KB), 70 Ns, 40-pin SOJ package DRAM ICs. CAUTION Install the chip in the correct orientation. Failure to do so will destroy the DRAM.. Video Slots Boot Device Priority The boot device priority is controlled by the Boot Device Ordering submenu of the Configuration menu of the Setup utility.
DIMM Slot LED Blink Codes System Board LED 0 LED 1 LED 2 LED 3 Processor Error Codes Processor errors are indicated by blinking patterns of the DIMM slot LEDs that alternate at 1 Hz, as listed below: Processor Error Status Indications ²...
Parts List Description Replacement Exchange Chassis Assembly Not orderable Top Cover 5064-1987 Side Cover 5064-1986 Cage Assy, Hot-Swap Mass Storage 5063-5671 Light Pipe 5041-1099 Backplane PCA, Hot-Swap Cage D3604-63003 Hot Swap Cage Bezel 5042-2108 Hot Swap Cage Bezel lock 5064-3503 tray, Hot Swap, D3349B D3583-69004...
Denmark 8120-2956 Switzerland 8120-2104 Europe 8120-1689 United Kingdom 8120-1351 Mass Storage Cables Cabling Label Location Description Part Number System backplane SCSI 5-connector, wide (68-pin) SCSI 5183-2412 connector to upper-shelf SCSI cable w/built-in terminator devices System backplane IDE 3-connector IDE cable 5183-2411 connector to IDE devices (CD- ROM or other)
Specifications Operating Temperature 5 to 35 C (41 to 95 F) Non-operating Temperature -40° to +70° C (-40° to +158° F) Operating Humidity 20% to 80% relative humidity (noncondensing) Non-operating Humidity 90% relative humidity (noncondensing) Operating Altitude 3,045 m (10,000 ft) Non-operating Altitude 12,180 m (40,000 ft) Height...
HP NetServer LD Pro System Views Flexible Disk Control CD-ROM Panel Hot Swap Subsystem Keyboard, mouse, serial, and display connectors External SCSI port connectors...
Control Panel H ard D is k A c ti vity L i g h t Ye ll o w = E m b e d d ed S C SI o r ID E b u s a c t ive K ey b o ar d L o c k L ig h t Yel lo w = k ey b o ar d Po w er -On L i g h t...
System Board Connectors, Switches, and Jumpers The table below explains the system board markings for all connectors. Connector Number IDE disk drive cable Keyboard Serial (2) Video J11— J14 PCI slots J6— J7 EISA/ISA slots J34, J35 Fans A, B Power supply on A PS1: J19 PS2: J19 Power supply...
System Switches and Jumper Descriptions Remote Assistant Connector J25 This connector is used by the HP Remote Assistant Accessory, a 32-bit EISA Bus Master board used to remotely monitor server functionality. For additional information on this product, see the documentation that comes with it.
Switch Function Default CONFIG VALID: Saves or erases the current configuration information in NVRAM and CMOS. ON: Saves the current configuration. OFF: Erases the current system configuration. CONFIG UNLOCK: Prevents or allows the current system configuration maintained in NVRAM and CMOS to be changed. ON: Unlocked.
Processor Board LED Blink Codes The processor board in the NetServer LD Pro contains LEDs that can indicate memory errors and processor errors. When a memory error exists, the LEDs are either on, off, or flash repeatedly a constant memory error code.
LED Processor Error Codes Alternating LED Codes: LED LED LED LED Definition Action ON-OFF-OFF-ON & Processor chip Check fans for function. Wait for system to OFF-ON-ON-OFF overtemperature cool down (20-25 minutes) and press the Reset button OFF-OFF-ON-ON & Primary processor chip Install processor chip in primary socket ON-ON-OFF-OFF (processor #1) not installed...
Page 43
If you have a system with a mixture of PCI and ISA or EISA boards perform the following: 1. Install the PCI controller board in slot 9. 2. Go to the EISA Configuration Utility. 3. Select "Step 3: View or edit details." 4.
NOTE In order to optimize PCI board BIOS installation, you need to leave the largest open range of memory possible. Group the EISA and ISA board BIOSs at either the beginning or end of the 0C8000h through 0DFFFFh range. Cabling Configurations Duplex, Non-Disk Array Model with Internal Controller This is a standard mass storage configuration as shipped from HP.
Duplex Disk Array Configuration with Dual Channel PCI Controller Board This is one of several possible optional mass storage configurations. You are not limited to the configurations shown on this CD-ROM; this is only given as an example. Flexible Disk Drive SCSI Terminator built into cable...
Technical Information Label with configuration information Always set switches 1, 2 and 6 to Off. Switch Function Settings C Bus Setting Always set to Off C Bus Setting Always set to Off High/Low Addresses Sets drives to upper eight SCSI addresses. Sets SCSI addresses for upper or lower eight Sets drives to lower eight SCSI addresses.
Parts List NOTE The part numbers in the list were the ones that were available at the time of publication. Part numbers may change after publication. HP's parts price list database will generally contain a reference to the revised part number. If a system board needs to be replaced, remove processor board and any added accessory boards, and keep them with the server under repair.
C cable, system board to 3-pin I C cable 5182-4535 hot-swap backplane Keyboards Language HP Part Number Language HP Part Number D4950-63001 Danish D4950-63016 Arab/French D4950-63025 Fr-Canadian D4950-63002 Portuguese D4950-63027 German D4950-63003 Cyrillic D4950-63030 Spanish D4950-63004 Belgian/Flemish D4950-63014 French D4950-63005 Italian D4950-63017 Norwegian...
Page 52
Server Footprint 369 x 474.71 mm (14.53 x 18.89 in) System Weight 50-70lb (22.7-31.8kg), depending on configuration Keyboard Height 3.4 cm (1.4 in) Width 46.8 cm (18.4 in) Depth 19.8 cm (7.8 in) Weight 1.9 kilograms (4.2 lb.) Cable Length Keyboard cable 3 m (9.9 ft) Ventilated Clearance...
HP NetServer LE System Views Control Panel Detail Reset Desktop Position: Lock 5 4 3 2 1 SERIAL B SER IAL A SC SI SERIAL B SERIAL A SCSI Mouse Video Parallel Keyboard...
Exploded View HP NetServer LE Parts List NOTE The part numbers in the list were the ones that were available at the time of publication. Part numbers may change after publication. HP's parts price list database will generally contain a reference to the revised part number. If a system board needs to be replaced, remove RTC module, any video DRAM chips, memory modules, processor board, any added accessory boards, and keep them with the server under repair.
Spanish C1405-60304 Korea/Hangul C1405-60321 French C1405-60305 Taiwan C1405-60323 Norway C1405-60309 Arab/French C1405-60325 Swiss C1405-60311 Portuguese C1405-60327 Swedish C1405-60312 Cyrillic C1405-60330 C1405-60313 Japan/Kanji C1414-60001 HP NetServer LE Power Cords Country HP Part Number Country HP Part Number Australia/New Zealand 8120-1369 India/South Africa 8120-4211 Canada/United States 8120-1751...
System Board Jumpers and Switches The following table explains all connector points, sockets, and switches on the system board. Num. Purpose Num. Purpose Keyboard Mouse Connector Video Connector External SCSI connector Serial A Serial B Parallel J8-J12 Accessory Boards Slots Optional Battery Internal SCSI Connector Power Connector...
Memory Configuration You can install any HP supported 4 MB, 8 MB, 16 MB, and 32 MB SIMMs in any socket and any arrangement. Video Memory - DRAM Install two additional DRAM chips to upgrade the server to 512 KB of RAM which lets the display use resolutions of 640x480 with 256 colors and 800x600 with 256 colors.
2. Make a backup copy of your current CONFIG.SYS file by entering; COPY CONFIG.SYS CONFIG.BAK 3. Copy the SET640K.SYS file from NetServer #2 diskette to NetServer #1 diskette by entering; COPY B:SET640K.SYS A:\ (If you do not have a second flexible disk drive, DOS treats drive A as both drive A and drive B and prompts you to insert disks.) 4.
HP NetServer LF System Views Control panel Mass storage shelf 1 (flexible disk drive) Mass storage shelf 9 Keyboard Mouse Serial port B Serial port A Parallel port LPT1 Monitor External SCSI port Slot 9 - PCI Slot 8 - PCI Slot 7 - EISA/ISA Cover screws (5) Slot 1 - EISA/ISA...
Control Panel Hard disk activity lights Reset button Keyboard lock light Power-on light Keyboard lock Power button Reset button Power button Turns the server on and off. Note that when the server is turned off, the power to the internal circuitry and mass storage devices is disabled; however, AC power is still applied to the power supply.
Parts List NOTE The part numbers in the list were the ones that were available at the time of publication. Part numbers may change after publication. HP's parts price list database will generally contain a reference to the revised part number. If a system board needs to be replaced, remove the ROM chip, processor board, any added accessory boards, and keep them with the server under repair.
Description Replacement Exchange Internal IDE-HDD Cable 5182-0016 LF SCSI Cable 5182-0066 LF SCSI terminator (Slick) 0960-0888 Diagnostic Assistant Diskette 5011-1941 * Not on exploded view ** Directly replaces 486/66 Processor Board in later model systems. For earlier systems (Serial No. xxxxS8xxxx or xxxxS0xxxx) use this board, plus 256 KB cache (0960-0899), plus bracket (5002-3243) Keyboards Language...
Processor Boards New 486/66 Processor Board CPU TYPE Cache module installation DX2 / DX4 DX2D Bank 0 Bank 1/2 Bank 3/4 CPU VOLTAGE MULTI J4, J5 are in these positions for SELECT TRIPLE both DX2/66 and DX4/100 CPU's DOUBLE DX2/66 DX4/100 Old 486/66 Processor Board Bank 3/4...
3.3V PS REMOTE PS ON SW1 Switch and Default Settings FLASH WRITE ENABLE BOOT LOCK DISABLE CONFIG VALID CONFIG UNLOCK PASSWORD ENABLE SMI# ENABLE IO CTRL ENABLE VIDEO ENABLE Switch Function Default FLASH WRITE ENABLE: Enables or disables one of the two levels of flash ROM write protection (the other level of protection is controlled by the HP Update Utility).
Memory Memory for the HP NetServer LF is installed on the processor board. The Intel 486 processor board has 8 MB of single-density base memory installed in bank 0. This memory is not customer removable and can only be single-density. There are two banks (four sockets) available for expansion memory which can be single or double density.
HP NetServer LH System Views Flexible Disk Control CD-ROM Panel Hot Swap Subsystem Keyboard, mouse, serial, and display connectors SCSI port connectors HP NetServer LH Pro...
Page 72
Keyboard, Mouse, Keyboard, Mouse, serial, and display serial, and display connectors connectors SCSI port SCSI port connectors connectors HP NetServer LH HP NetServer LH Plus...
Page 73
Control Panel H a r d D i s k A c t i vi t y L ig h t 2 H a r d D is k A c ti vi t y L ig h t 1 Ye l l o w = E m b e d d e d S C S I B Ye l l o w = E m b e d d e d S C S I A b u s a c t i v e...
Cover CAUTION The cover is an integral part of the server. The server must be operated with the cover in place to ensure proper airflow for continued reliability and to maintain compliance with radio frequency interference and safety standards.
HP NetServer LH Parts List NOTE The part numbers in the list were the ones that were available at the time of publication. Part numbers may change after publication. HP's parts price list database will generally contain a reference to the revised part number. If a system board needs to be replaced, remove processor board and any added accessory boards, and keep them with the server under repair.
Fig # Description Replacement Exchange Bracket-CPU Mount 5002-3243 HP DAC Controller Board PCI Hold Down Bracket 5002-3279 LH Control Panel Bezel 5063-0381 LH Control Panel PCA 5063-0382 Cardguide Assembly 5063-5697 Fan Assembly 3160-1004 Chassis Foot 5041-1082 Power Supply - 350W 5063-5690 LH System ROM D3353-80204...
HP NetServer LH Plus Parts List NOTE The part numbers in the list were the ones that were available at the time of publication. Part numbers may change after publication. HP's parts price list database will generally contain a reference to the revised part number. If a system board needs to be replaced, remove processor board and any added accessory boards, and keep them with the server under repair.
Intl narrow (50-pin) to wide Fast/wide SCSI adapter (50 5182-4550 (68-pin) adapter pin to 68 pin) C cable, system board to hot- 3-pin I C cable 5182-4535 swap backplane HP NetServer LH Pro Exploded Views...
Page 85
NOTE The part numbers in the list were the ones that were available at the time of publication. Part numbers may change after publication. HP's parts price list database will generally contain a reference to the revised part number. If a system board needs to be replaced, remove processor board and any added accessory boards, and keep them with the server under repair.
HP NetServer LH Keyboards Language HP Part Number Language HP Part Number C1405-60301 Danish C1405-60316 Arab/French C1405-60325 Fr-Canada C1405-60302 Portuguese C1405-60327 German C1405-60303 Cyrillic C1405-60330 Spanish C1405-60304 Japan/Kanji C1414-60001 French C1405-60305 Italian C1405-60317 Norway C1405-60309 Arab/English C1405-60320 Swiss C1405-60311 Korea/Hangu C1405-60321 Swedish C1405-60312...
Keyboard Mouse IO Panel Serial port B Connectors Serial port A Side view Parallel port LPT1 Monitor Power Supply Enable Connector PS1/P1 PS4/P4 PS2/P2 Control Panel HP Remote Assistant Flexible PS3/P3 Connector Connector Disk Connector IDE Disk Drive Cable Connector Battery Connectors Power Supply...
Power supply on A Remote Assistant Power supply PS1-J19, PS2-J19 SCSI A (IN=FAST) PS3-J20, P4-J122 Color/Monochrome PS4-J17 Power supply on B -3v Power Module System Switches Processor board System ROM SCSI B (IN=FAST) System Switches and Jumper Descriptions Remote Assistant Connector - J22 (LH) and J25 (LH Plus/LH Pro) This connector is used by the HP Remote Assistant Accessory, a 32-bit EISA Bus Master board used to remotely monitor server functionality.
Page 91
System Board Switch SW1 SW1 Default Settings: Flash W rite Enable Boot Lock Disable Config Valid Config Unlock Password Enable NMI LOG Enable IO Control Enable Video Enable LH Plus / LH Pro Flash Write Enable Boot Lock Disable Config Valid Config Unlock Password Enable SMI # Enable...
Switch Function Default IO CTRL ENABLE: Enables or disables onboard flexible disk drive controller, IDE controller, and serial and parallel ports. ON: I/O controller enabled. OFF: I/O controller disabled. VIDEO ENABLE: Enables or disables built-in video. Disable the built-in video only if you have a separate video board installed in the server. ON: Enables built-in video.
Page 93
On = Steady green Flash = Regular, slow flash (1 Hz) Blink = Regular, fast flash Double-blink = Irregular, double-flash The diagnostic LEDs are located on the the processor board, are labeled DIMM 0 through 3, and correspond to DIMM sockets 0 through 3. The LEDs are visible from either side of the board, and can also be viewed through the NetServer's rear panel cooling perforations.
Reset button OFF-OFF-ON-ON & Primary processor chip Install processor chip in primary socket ON-ON-OFF-OFF (processor #1) not installed ON-OFF-OFF-OFF & Primary Voltage Regulator Replace primary OFF-ON-ON-ON Module fault Voltage Regulator Module OFF-ON-OFF-OFF & Secondary Voltage Regulator Replace secondary Voltage Regulator ON-OFF-ON-ON Module fault Module...
Page 95
Duplex, non-disk array model with internal controller (standard model) Flexible Disk Drive External terminator built into cable CD-ROM SCSI or IDE Device System Board Internal terminator built into board SCSI B SCSI A Hot Swap Subsystem Default Switch Settings These are the default SCSI address settings for this model. SCSI ID 2 is reserved for an added DAT (Digital Audio Tape) drive that UPPER CAGE...
Page 96
Non-duplex, disk array model with PCI controller board (standard model) or EISA controller board Flexible Disk Drive External terminator built into cable CD-ROM SCSI or IDE Device System Board Internal terminator built into PCI/EISA Board board SCSI B SCSI A Hot Swap Subsystem This cable must be routed through the rear...
Configuring Switch Settings on the Hot Swap Subsystem Switch setting combinations are given in the table below. UPPER CAGE LOWER CAGE Switch Function Settings C Bus Setting Always set to Off C Bus Setting Always set to Off High/Low Addresses Always set to Off SCSI Address Zero On: Sets middle shelf in the cage (shelf 2 or shelf 5) to...
Hot Swap Subsystem SCSI Address Settings Switches 4 and 6 determine the SCSI address setting for each shelf in the hot swap subsystem. The following table describes the settings and the resulting shelf SCSI address. NOTE For information on changing the SCSI address setting on the CD-ROM drive, see the Technical Information Label on the CD-ROM drive.
HP NetServer LH 3 and LH 3r System Views Front Control Panel Control Description Lock (LH 3 only) Locks system to prevent unauthorized use. DC Power Switchand indicator light Turns the NetServer on and off. This switch is behind the protective door on the front panel. Push once to turn on, again to turn off.
Page 100
Control Description Resets the NetServer from internal ROM. This switch is behind the protective RESET door on the front panel. Keyboard lockand indicator light Locks system keyboard to prevent unauthorized use. Status screen Reports various types of system status. The buttons below the screen control these menu functions Return to a previous selection.
Rear View Remote Management Port Serial B Port Serial A Port Parallel Port Mouse Port Keyboard Port Monitor Port Power Supplies Power Connector Covers (LH 3) Cover 3 Cover 1 Cover 2 Cover 2 Cover 3 Cover 1 Covers (LH 3r) Cover 1 Cover 2 Cover 3...
Memory There are four DIMM sockets on the system board for memory expansion. You can use 64 MB, 128 MB, and 256 MB DIMMs for a maximum capacity of 1 GB of RAM. The minimum memory configuration for the NetServer LH 3/LH 3r is one 128 MB DIMM. The system board DIMM sockets are numbered from 0 to 3.
DIMM Slot LED Blink Codes LED Error Codes Error Condition Corrective Action = LED on = LED off Alternating Blink Code: LED LED LED LED Check that primary voltage regulator module Primary VRM Failure (VRM) is correctly seated. If problem persists, replace VRM.
Description Replacement Exchange Fan assembly, rear chassis 5064-3553 Fan assembly, power supply 5064-3538 Fan assembly, CPU 5064-3531 Power supply module, 300W 5064-6603 Power supply cage 5064-6605 5064-6604 Battery 3V 1420-0356 Front panel assembly, pedestal version 5067-4214 Front panel assembly, rack version 5064-4639 Installation handles, rack version (4) 5002-5191...
Power Cords Country Part Number Country Part Number Australia/New 8120-1369 India/South Africa 8120-4211 Zealand Canada/United 8120-1751 Japan 8120-4753 States Denmark 8120-2956 Switzerland 8120-2104 Europe 8120-1689 United Kingdom 8120-1351 Hot-Swap Hard Disk Drive LED Status and Activity Indicators Each hot-swap hard disk drive module has two LED apertures on its front, one for power status and one for activity status, as shown below.
Specifications Operating Temperature 5 to 35 C (41 to 95 F) Non-operating -40° to +65° C (-40° to +149° F) Temperature Operating Humidity 20% to 80% relative humidity, non-condensing Non-operating Humidity 5% to 95% relative humidity, non-condensing Operating Altitude -30 to 3,000 m (~10,000 ft) Non-operating Altitude -30 to 12,000 m (~40,000 ft) Minimum Clearance...
HP NetServer LH 4 and LH 4r System Information System Views HP NetServer LH 4 (Pedestal) HP NetServer LH 4r (Rack-Optimized) Front Control Panel Control Description Lock (LH 4 only) Locks system to prevent unauthorized use. DC Power Switchand indicator light Turns the NetServer on and off.
Page 112
Control Description RESET Resets the NetServer from internal ROM. This switch is behind the protective door on the front panel. Keyboard lockand indicator light Locks system keyboard to prevent unauthorized use. Status screen Reports various types of system status. The buttons below the screen control these menu functions Return to a previous selection.
Rear View Remote Management Port Serial B Port Serial A Port Parallel Port Mouse Port Keyboard Port Monitor Port Power Supplies Power Connector Covers (LH 4) Cover 3 Cover 1 Cover 2 Cover 2 Cover 3 Cover 1...
Covers (LH 4r) Cover 1 Cover 2 Cover 3 Memory The two memory boards (Memory A and Memory B) are located on the system board assembly, beneath the memory cage cover. Both memory boards are required. Each board has slots for eight DIMMs. The following rules must be observed when adding memory: DIMMs are added four at a time - two per memory card.
Processor speed and system DIP switches VRM 3/4 VRM 3 Ext Batt Processor 4 Battery Serial B port Processor 3 Serial A port Memory B Processor 2 Parallel port Processor 1 Mouse port Memory A Keyboard port VRM 1/2 Monitor port VRM 2 VRM 1 Note: Processor slots without processors have terminators.
The Boot Device Ordering submenu contains the following options: Floppy check: Enables or disables verification of flexible disk drive type during boot Summary screen: Enables or disables display of a screen of system configuration information. Boot Device Priority: Allows you to rearrange the following default order in which drive types are searched for the operating system: CD-ROM drive with bootable CD-ROM Flexible Disk with bootable flexible disk...
Parts List NOTE These part numbers are the numbers available at the time of publication. Part numbers may be revised after the publication date. Description Replacement Exchange System board PCA (PCA only) D7014-63001 D7014-69001 I/O PCA D7092-63000 D7092-69000 Memory PCA D6969-63001 D6969-69001 Backplane PCA...
Page 119
Description Replacement Exchange Hot-swap filler Not orderable as replacement Hot-swap drive spacer Not orderable as replacement Hot-swap mass storage expansion bay cover plate Not orderable Not orderable Hot-swap tray, half-height D6127A Hot-swap tray, low-profile D6128A Non-hot-swap tray, hard disk drive (3 ea.) D2198B Non-hot-swap tray, removable media device (2 ea.) D2199A...
Hot-Swap Hard Disk Drive LED Status and Activity Indicators Each hot-swap hard disk drive module has two LED apertures on its front, one for power status and one for activity status. Activity Status LED Aperture Power Status LED Aperture System Board Configuration Switches VRM 3...
System Switches Off On Always on Processor speed (see table below) Always off Processor speed (see table below) On = Clear config On = Clear p/w Always off Always off Processor Speed: 400 450 500 Switch 2: Switch 4: Note: Only processor speeds for the 100 MHz bus are supported.
Cables and Part Numbers Cable Description Part Number Internal SCSI (Wide) LVD Cable (SCSI A to Primary Mass Storage) 5183-3444 Internal SCSI (Wide) LVD Cable (DAC to Primary Mass Storage)* 5183-6527 Internal SCSI (Wide) LVD Cable (DAC to Secondary Mass Storage)* 5183-6528 Internal SCSI (Wide) LVD Cable (SCSI B to Secondary Mass Storage) 5183-6567 Internal SE SCSI Cable...
Page 124
Height 494.8 mm (19.5 in) Width 350.5 mm (13.8 in) Depth 724.2 mm (28.5 in) Weight 35 - 50 kg (77 - 110 lb) Weight and Dimensions - LH 4r Height 354.7 mm (14 in) Width 482.6 mm (19 in) Depth 749.2 mm (29.5 in) Weight...
HP NetServer LM System Views Front and Rear Views Shelf 1 R e s e t Control Panel Mass Storage Device Shelves Shelf 9 AC power Keyboard Mouse Serial port B Serial port A AC line Parallel port LPT1 select switch Built-in video Padlock or External SCSI...
Parts List NOTE The part numbers in the list were the ones that were available at the time of publication. Part numbers may change after publication. HP's parts price list database will generally contain a reference to the revised part number. If a system board needs to be replaced, any video DRAM chips, memory modules, processor board, any added accessory boards, and keep them with the server under repair.
HP NetServer LM Power Cords Country HP Part Number Country HP Part Number Australia/New 8120-1369 India/South Africa 8120-4211 Zealand Canada/United 8120-1751 Japan 8120-4753 States Denmark 8120-2956 Switzerland 8120-2104 Europe 8120-1689 United Kingdom 8120-1351 System Board Video memory DRAM sockets Power supply Power supply Control panel connectors...
System Board Jumper Locations E0722 E0721 E0720 E0392 E0391 E0390 E0292 E0291 E0290 E0190 System Board Jumper Settings Jumper Function Default Flash BOOT. When the jumper is on pins 1 and 2, the Flash ROM E0190 1 to 2 can be reflashed. If the Flash ROM is corrupt, even reading from the flexible disk drive does not work, move the jumper to 2-3 to allow access to protected code on the Flash EPROM (boot code protected sector) that should allow the Flash from the BIOS.
NOTE Only DRAMs from certain manufacturers have been tested for compatibility with the HP NetServer LM Series. Hewlett-Packard does not supply the DRAM upgrade. Consult the HP PC Bulletin Board Service at 1-408-553-3500 for a current list of supported DRAM upgrades.
Instruments To take advantage of the upgrade, you must also install the appropriate drivers. Consult the HP PC bulletin board for a list of the required drivers. Hewlett-Packard does not supply or support the drivers. CAUTION Apply gentle pressure on the pins. They can bend easily. If a pin does not align with a hole, carefully use needle-nose pliers to straighten the pin.
ID 6 Jumper Jumper ID 7 functional 1740 SCSI Host Adapter Configuration Configuring a 1740 SCSI adapter (either the HP D2649A or D1681A) may cause a "Shadow RAM diagnostic failed" error message. The SCSI BIOS uses the last 128 bytes of the 32 KB ROM space as a RAM buffer. In the 1740's .CFG file, there is a "WRITABLE"...
If more than three drives are installed, remove the Delayed Spin-Up jumper on drives with addresses 3, 4, 5, and 6. To find the Delayed Spin-Up jumper, orient the drive so the circuit board is on top and the power/SCSI connector is facing away from you.
In the EISA Configuration Utility, select the Hard Drive 1 (or 2) to be Drive Type 2 or 48 (User Definable) at the end of the list of choices for any IDE hard disk drives installed. Do not use Hard Disk Auto Configuration. Verify these parameters as the drive definition: Parameter 270 MB...
HP NetServer LPr System Views Front Panel Controls CD-ROM Drive Drive Activity LED Reset Switch Power ON/OFF LED Drive Error LED Power On/Off Switch Fan Failure LED Hot Swap Drive Shelf Over-temperature LED SCSI ID #0 Floppy Disk Drive Hot Swap Drive Shelf SCSI ID #1 Power ON/OFF Drive Error...
Drive Active LED LED goes on (green) to indicate access over the LPr's embedded SCSI bus. This includes access to both internal and external drives. Drive Error LED LED flashes red to indicate that one of the two drives in the hot-swap bays has failed and must be replaced.
Covers Memory The NetServer LPr's main memory is implemented with 5V SDRAM DIMMs (Dual In-Line Memory Modules). The NetServer LPr ships with at least 64 MB of main memory and supports up to 1 GB. Memory is available in the following DIMM capacities: 64, 128, and 256 MB. There are four DIMM sockets on the system board. DIMMs may be installed in any combination in any socket.
DIMM Notches Keys Retaining Clips Video Memory The HP NetServer LPr comes standard with a 1 MB frame buffer to support video displays of 1024 (horizontal pixels) x768 (vertical lines) x 256 (colors per pixel) at refresh rates up to 72 Hz. You can upgrade the frame buffer to 2 MB to support 1280 x 1024 by adding two memory chips.
Boot Device Priority By default, the HP NetServer searches for bootable devices in the order shown below. CD-ROM Drive Floppy Disk Drive Embedded SCSI Controller, starting with SCSI ID 0 PCI Slots in the order 3, 2, and 1 On each controller, the server scans for a boot device starting at device ID 0 and works up from there. The controller is always SCSI ID 7.
Page 142
Slot 3 Slot 2 Slot 1 CAUTION Do not bend the PCI card to fit it into the slot. Check to make sure you removed any handles or board extenders. Remote Control Card Refer to the Top Tools Administration Guide for Remote Control along with the upgrade kit documentation for information on the remote control card.
Page 143
HP NetRAID Card NOTE If there are other SCSI controllers on the PCI bus, the slot will affect boot order. See the Boot Device Priority. SCSI Cable SCSI Repeater Card HP NetRAID Adapter SCSI Cable...
Processor Module NOTE Be sure that the VRM and the processor module associated with it are both in primary or secondary slots. New processors are added. See the Technical Reference Card for the latest switch settings. Secondary Processor VRM Slot CPU Processor Secondary Processor Switch...
Do not touch VRM Processor components Module Secondary VRM Slot Secondary Processor Slot NOTE Be sure that the VRM and the processor module associated with it are both in primary or secondary slots. Exploded Views...
Parts List * This part is not on an exploded view. Description Replacement Exchange Top Cover 5064-7036 I/O ("Riser") Board D6129-63000 D6129-69000 Fan pack 5064-5858 SCSI backplane D6021-63030 SCSI management board D6021-63031 Hot-swappable SCSI drive orderable as accessories Hot-swappable drive kit Hot-swap bay filler panel (not orderable) Floppy disk drive...
System Board Illustration Voltage Regulator Processor Module Processor Module Module #1 Slot Slot #2 Voltage Regulator Slot #1 Module #2 Slot Battery Serial B Port Connector Processor Serial A Port Module Connector Parallel Port Connector DIMM Slot 0 Mouse DIMM Slot 1 Connector DIMM Slot 2 Keyboard...
Specifications Temperature Operating 5° to 35° C (41° to 95° F) Non-operating -40° to +65° C (-40° to +149° F) Humidity (non-condensing) Operating 20% to 80% relative humidity, non-condensing Non-operating 5% to 95% relative humidity, non-condensing Altitude Operating -30 to 3,000 m (~ 10,000 ft) Non-operating -30 to 12,000 m (~ 40,000 ft) Thermal Output...
Control Panel Description Hard Disk Activity Light 2 Hard Disk Activity Light 1 Yellow = Embedded SCSI Yellow = Embedded SCSI A B bus active or IDE bus active Keyboard Lock Light Power-On Light Yellow = Keyboard Green = Power is on is locked Power Button Keyboard Lock Button...
Hard disk activity light 1 connector Hard disk activity light 2 connector Cover CAUTION The cover is an integral part of the NetServer. The NetServer must be operated with the cover in place to ensure proper airflow for continued reliability and to maintain compliance with radio frequency interference and safety standards.
Parts List NOTE The part numbers in the list were the ones that were available at the time of publication. Part numbers may change after publication. HP's parts price list database will generally contain a reference to the revised part number. If a system board needs to be replaced, remove processor board and any added accessory boards, and keep them with the server under repair.
Description Replacement Exchange EISA/PCI Hold Down Plate not orderable CPU Metal Hold Down Plate not orderable ECC Memory Board D2971-63006 LS 100 Mhz Processor Board D3574-63001 D3574-69001 LS 100D Dual Processor Board D3575-63001 D3575-69001 LS 133 Processor Board D3613-63001 D3613-69001 LS 133 Dual Processor Board D3614-63001 D3614-69001...
Arab/English C1405-60320 Swiss C1405-60311 Korea/Hangu C1405-60321 Swedish C1405-60312 Taiwan C1405-60323 C1405-60313 Power Cords Country HP Part Number Country HP Part Number Australia/New Zealand 8120-1369 India/South Africa 8120-4211 Canada/United States 8120-1751 Japan 8120-4753 Denmark 8120-2956 Switzerland 8120-2104 Europe 8120-1689 United Kingdom 8120-1351 Mass Storage Cables If you need additional cables, the cables are not available separately, but only by ordering the HP Cable Kit -...
System Board Keyboard Mouse IO Panel Serial port B Connectors Serial port A Side view Parallel port LPT1 Monitor CMOS CLEAR PWD CLR Flash Enable Flexible Disk Dual CPU Power Supply Flexible Power/PS5 Enable Connector Disk Connector 1.44 MB Power Supply Connectors Control Panel Power Control PS4 PS1...
System Board Connectors Connector Number Connector Number IDE disk drive cable J9F1 Flexible disk drive J9F2 Keyboard J9A1 Mouse J9A1 Video J7A1 Parallel J7A1 Serial J8A1 SCSI port A J0J1 SCSI port B J0G2 Battery (Clock Module) U7D1 PCI slots P2-2, P2-1 EISA/ISA slots M6, M5, M4,...
Switch/ Description Default Jumper Configuration Switches - Switch S8C1 S8C1 CMOS CLEAR PWD CLR OFF - default Flash Enable OFF - Default CMOS Clear: Setting this switch to ON clears CMOS and set the real- time clock (RTC) to the manufacturing defaults. ON - Password Clear: Setting this switch to ON clears the password when Default...
Video Memory - DRAM Video memory can be increased to 1 MB. The built in video subsystem comes with a Cirrus Controller with 512 KB of internal video memory. The internal, integrated Cirrus super VGA controller is fully compatible with these video standards: CGA, EGA, Hercules Graphics, MDA, and VGA.
Page 164
Duplex, non-disk array model with internal controller (standard model) Flexible Disk Drive External terminator built into cable CD-ROM SCSI or IDE Device System Board Internal terminator built into board SCSI B SCSI A Hot Swap Subsystem UPPER CAGE SCSI ID Default Switch Settings These are the default SCSI address settings for this model.
Page 165
Non-duplex, disk array model with PCI controller board (standard model) Flexible Disk Drive External terminator built into cable CD-ROM SCSI or IDE Device 68 to 50 pin adapter System Board Internal terminator built into board PCI Board SCSI B SCSI A Hot Swap Subsystem Ext Conn...
Configuring Switch Settings on the Hot Swap Subsystem Switches 3, 4 and 6 determine the SCSI address of the shelf. UPPER CAGE LOWER CAGE The switch 6 setting determines upper and lower cage functionality. Switches 1 and 2 are always set to Off. Switch Function Settings...
Hot Swap Subsystem SCSI Address Settings Switches 3, 4, and 6 determine the SCSI address setting for each shelf in the hot swap subsystem. The following table describes the settings and the resulting shelf SCSI address. NOTE For information on changing the SCSI address setting on the CD-ROM drive, see the Technical Information Label on the CD-ROM drive.