NETGEAR GS748AT - ProSafe Gigabit Smart Switch Administration Manual page 59

Software administration manual
Hide thumbs Also See for GS748AT - ProSafe Gigabit Smart Switch:
Table of Contents

Advertisement

Trap Filter Settings
Filter Name – Select the user-defined notification filter from the list.
Trap Filter Settings
Object ID Subtree – Enter the OID for which notifications are sent or blocked. If a filter
is attached to an OID, traps or informs are generated and sent to the trap recipients. OIDs
are selected from either the Select field or the Object ID field.
Filter Type – Select whether to send traps or informs relating to the selected OID. The
possible field values are:
Excluded – Do not send traps or informs.
Included – Send traps or informs.
2. Select the Filter Name from the list in the provided field.
3. Select the trap filter content entry from the OID table.
4. Enter the Object ID Subtree in the provided field in the first row.
5. Select the Filter Type from the list in the provided field in the first row.
6. Click APPLY to update the device.
To add a new trap filter content entry:
1. Click System > SNMP > SNMPv3 > Trap Filter Content. The SNMPv3 Trap Filter Content
screen displays.
2. Select the Filter Name from the list in the provided field.
3. Enter the Object ID Subtree in the provided field in the first row.
4. Select the Filter Type from the list in the provided field in the first row.
5. Click ADD to update the device.
To remove a trap filter content entry:
1. Click System > SNMP > SNMPv3 > Trap Filter Content. The SNMPv3 Trap Filter Content
screen displays.
2. Select the Filter Name from the list in the provided field.
3. Select the trap filter content entry.
4. Click DELETE to remove the entry.
Managing System Settings
GS700AT Smart Switch Software Administration Manual
v1.0, October 2008
3-50

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gs748at-100nasGs700at smart switch

Table of Contents