Replacing Photo Conductor Unit (PCU)

When 'Replace photoconductor unit' appears on the panel display, it is time to
replace the photo couductor unit.
R WARNING:
• Do not incinerate the photoconductor unit. Toner dust might ignite
when exposed to an open flame. Dispose of the used photoconductor
unit in accordance with local regulations for plastics.
Note
❒ Do not tilt used PCU after removing it from the machine. If you do, toner
might fall out.
❒ Do not hold the developer cartridge when removing the used PCU from your
machine. If you do, the cartridge might come unlocked and fall.
❒ Do not touch the photo couductor. If you do, abnormal copies might be made.
❒ Before you remove the used PCU from the machine, wait until the machine
has completely stopped and is making no sound. Failure to take this precau-
tion could result in a fault.
❒ If there are misfeeds, remove the misfed paper before removing the used
PCU.
❒ Be sure to remove the sealing tape before setting the new PCU. Leaving it on
could cause a fault.
❒ After replacing the PCU, the machine will take about 1 minutes to initialize.
During this period, do not open the front cover or turn off the main switch. If
you do, a fault might occur.
A A A A
If the duplex unit is installed, open the duplex unit by pushing the catch
upwards.