Chapter 6—Setting Up the Printer
Thermal Transfer Printing
• Ribbon Constant
• Ribbon Factor
• Label Offset
• Ribbon Sensor
• Low Diameter
When adjusting the image darkness for non-Intermec media and transfer
ribbons, set the Ribbon Factor to the recommended value for the type
of thermal transfer ribbon. Set the Ribbon Constant at the value listed
below and decrease or increase it for lighter or darker images respectively
until you are satisfi ed with the printout quality. The Label Offset param-
eter is presently not used, so keep it at the default value 0.
General Paper Type Settings Guide (Thermal Transfer)
Type
Wax (Europe)
Wax (U.S.A.)
Wax/Resin (Europe)
Wax/Resin (U.S.A.)
Resin (Europe)
Resin (U.S.A.)
The Ribbon Sensor parameter is read-only. When performing a Testfeed
or when pressing the <Enter> key when the Ribbon Sensor menu is
displayed, the printer will feed out some media and autoadjust the sensor.
The resulting setting is displayed in the menu.
The Low Diameter parameter specifi es the diameter of the ribbon
supply roll, where SYSVAR(26) switches from 0 to 1. SYSVAR(26)
= 0 means that there is still a suffi cient supply of ribbon, whereas
SYSVAR(26) = 1 means that it is time to consider replacing the ribbon
supply. The diameter is expressed in millimetres (1 mm = 0.04 in.) and
an accuracy of ±3 mm can be expected. Note that this setting has little
effect unless SYSVAR(26) is read by a Fingerprint program. However,
Error 1083 "Ribbon Low" is reported at every tenth printing operation.
By default, the low diameter is 0, that is, the ribbon low function is
disabled.
58
(range 50 to 115)
(range 10 to 50)
(range -50 to 50)
(autoadjustment)
(range 25 to 80 mm)
Ribbon
Ribbon
Constant
Factor
80
25
65
25
90
25
75
25
100
30
90
30
Intermec EasyCoder PF4i—User's Guide (Fingerprint version)
Max Print Speed
8 dots/mm
11.81 dots/mm
150
150
150-200
150-200
200
200
125
125
125-150
125-150
150
150