Printer error recovery
LCD Message
No Cleaning Ro.
No Cassette
Hardware
TR Overheat
TR Broken
TR Sensor Broken
RR Overheat
RR Broken
RR Sensor Broken
Overcool
Head Overheat
EEProm Broken
MG Unconnected
MG Mechanical
MG Hardware
60
Possible Cause
The cleaning rollers are
missing.
The ink ribbon or retransfer
film cartridge is not
installed.
There is a hardware error.
The retransfer roller is too
hot.
The retransfer roller is not
working.
The retransfer roller
thermistor is not working.
The bend remedy roller is
too hot.
The bend remedy roller is
not working.
The bend remedy roller
thermistor is not working.
It is too cold for the printer
to operate.
The thermal head is
overheated.
EEPROM malfunction
Magnetic stripe module
connection error
Magnetic stripe
mechanical error
Magnetic stripe hardware
error
Solution
1 Reinstall the cleaning rollers.
2 Press RESET, and then ENTER to initialize the
printer.
"Cleaning the card cleaning rollers" on
3 See
page 44
for more information.
1 Install the cartridge(s) in printer.
2 Initialize the ink ribbon as described in
the ink ribbon" on page 16
3 Initialize the retransfer film as described in
"Initialize the retransfer film" on page 17
Turn the power switch off and then on again. Call for
service if the problem persists.
Turn the power switch off and then on again. Call for
service if the problem persists.
Turn the power switch off and then on again. Call for
service if the problem persists.
Turn the power switch off and then on again. Call for
service if the problem persists.
Turn the power switch off and then on again. Call for
service if the problem persists.
Turn the power switch off and then on again. Call for
service if the problem persists.
Turn the power switch off and then on again. Call for
service if the problem persists.
The temperature in the printer area is too low. Use at
the recommended operating environment temperature
"Operating environment" on
as described in
page 72
.
Turn the power switch off and allow the printer to cool
for approximately 10 minutes before turning power
back on.
Turn the power switch off and then on again. Call for
service if the problem persists.
Turn the power switch off and then on again. Call for
service if the problem persists.
Turn the power switch off and then on again. Call for
service if the problem persists.
Turn the power switch off and then on again. Call for
service if the problem persists.
RP90 Plus E and RL90 User Guide