System Design and Installation

Wiring External Regeneration Resistance

R7D-AP04L and R7D-AP04H
Connect an External Regeneration Resistor between the B1 and B2 terminals.
External Regeneration Resistor
B1
Servo Driver
B2
R7D-AP08H
Remove the short-circuit wiring between B2 and B2, and then connect an External Regeneration
Resistor between the B1 and B2 terminals.
External Regeneration Resistor
B1
Servo Driver
B2
← Remove
B3
3-42
Note When using the R88A-RR22047S, connect the
thermal switch output so that the power supply will
be shut off when open.
Note 1. The short-circuit wiring between B2 and B3 must be removed.
2. When using the R88A-RR22047S, connect the thermal switch
output so that the power supply will be shut off when open.
Chapter 3